17. Place retainer plate in cylinder barrel.
Note:(Remember to lubricate the
retainer plate and cylinder bushings
with clean filtered water).
19. Place pistons in retainer plate and
cylinder barrel, When pistons are placed,
tilt retainer plate for easier placement of
swash plate.
If swash plate has been disassembled from
mounting flange, see page 11 for assembly
of swash plate.
16. Place the spring guide and the retainer
guide on the cylinder shaft.
15. Place the 7 springs and 3 pins in cylinder
barrel. The pin holes are assymetric.
18. Ensure that retainer plate is oriented
correctly, i.e. with its slant surfaces
pointing downwards.
20. Place the guide pin in the housing.
21. Lubricate piston shoes and swash plate
with clean filtered water.
22. Mount assembled swash plate, using the
guide pin.