APP pump instruction APP 0.6-1.0, APP 1.5-2.5 and APP 3.0-3.5

7

180R9065  /  521B0733 /  DKCFN.PI.013.C4.2T  /  09.2012

Before start-up, loosen the top bleeding plug “C”. 

When water appears from the bleeding plug, 

retighten the plug. With its inlet line connected 

to the water supply or the tank, the pump is now 

started with open outlet port.

At the initial start of the system, the pump 

should be run without pressure for about  

5 minutes, thus removing possible impurities 

from pipes, hoses, etc. 

However, the system 

should be flushed before start-up – without the 

connected pump.

WARNING:

Make sure that the direction of rotation of the 

electric motor corresponds to the direction of 

rotation of the pump. Otherwise the pump will 

be damaged if a check valve is placed between 

pump and tank.

4. 

Initial start-up

5. Operation

5.1 Temperature

In case of lower operating temperatures, please 

contact the Danfoss Sales Organization.

5.2 Pressure

The inlet pressure must be min. 0.9 bar (13 psi) 

and max. 5 bar (72.5 psi) abs. At lower pressures 

the pump will cavitate, resulting in damage to 

the pump.

Max. pressure on the pump’s outlet line should 

be limited at 80 bar (1160 psi) continuously. 

Short-term pressure peaks (e.g. in connection 

with closing of a valve) of up to 100 bar (1450 psi) 

are acceptable.

NB:

The pump unit should include a pressure 

gauge on the high pressure side.

5.3  Dry running

When running, the pump must always be 

connected to the water supply in order to avoid 

damage if it should run dry.

In systems with water tank it is recommended to 

build in a level gauge in the tank to avoid the risk 

of running dry.

5.4 Disconnection

If the inlet line is disconnected from the water 

supply, the pump will be emptied of water 

through the disconnected inlet line.

When starting up again, follow the bleeding 

procedure described under section 4: Initial start 

up.

5.5 Storage

When preparing the pump for long-term storage 

or for temperatures below the freezing point, 

flush the pump with an anti-freeze medium type 

monopropylene glycol to prevent internal 

corrosion or frost in the pump.

For further information on anti-freeze media, 

please contact the Danfoss Sales Organization.

Recommended procedure:

5.5.1  Open-ended systems with water supply 

from tank

1. 

 Empty the tank of water and empty the 

pump housing through the lower bleeding 

plug. When the pump is empty, retighten 

the plug.

2. 

 Through the upper bleeding plug, fill the 

pump housing with anti-freeze medium. 

Pour anti-freeze medium into the tank. 

Connect a hose to the outlet of the pump 

and lead the other end of the hose back to 

tank.

3. 

 Quickly start and stop the pump. Make sure 

that the pump does not run dry. The pump 

is now protected against internal corrosion 

and frost.

Fluid temperature:

Min. +3° C to max. +50° C
Ambient temperature:

Min. 0° C to max. 50° C

Storage temperature: 

Min. -40° C to max. +70° C

Summary of Contents for APP 0.6

Page 1: ...APP 0 6 1 0 APP 1 5 2 5 and APP 3 0 3 5 MAKING MODERN LIVING POSSIBLE Lenntech info lenntech com Tel 31 152 610 900 www lenntech com Fax 31 152 616 289 info lenntech com Tel 31 152 610 900 www lenntec...

Page 2: ...ines for calculation of pressure losses 4 2 5 General comments on 4 3 Building up the pump unit 5 3 1 Mounting 5 3 2 Direction of rotation 5 3 3 Orientation 6 3 4 Protection from too high pressures 6...

Page 3: ...mp 2 Place the inlet filter before the tank 3 Dimension the inlet line to obtain mini mum pressure loss large flow area minimum pipe length minimum number of bends connections fittings with small pres...

Page 4: ...ng to below guidelines 2 5 General comments on Filtration A good ltration is vital to ensure a long and trouble free life of the pump When selecting a filter or strainer please note that filter materi...

Page 5: ...all to separate the inlet from the outlet end of the tank Monitoring It is recommended to continuously monitor the following conditions Water level in the tank Filter contamination Pressure inlet and...

Page 6: ...close to the pump as possible The opening characteristics of the valve must not result in peak pressures higher than 200 bar 2900 psi The valve outlet must not be connected directly to the pump suctio...

Page 7: ...ssure gauge on the high pressure side 5 3 Dry running When running the pump must always be connected to the water supply in order to avoid damage if it should run dry In systems with water tank it is...

Page 8: ...elf and there is thus no oil in the pump The pump requires no periodic replacements of seals and valve parts 6 2 Repair In case of irregular function in the pump please contact the Danfoss Sales Organ...

Reviews: