background image

Instruction 

APP pump instruction APP 0.6-1.0, APP 1.5-2.5 and APP 3.0-3.5

4

180R9065  /  521B0733 /  DKCFN.PI.013.C4.2T  /  09.2012

2.4   General guidelines for calculation of 

pressure losses

In order to avoid the risk of cavitation, the inlet 

pressure at the pump must be in accordance 

with the specifications mentioned in Data 

sheet (521B0850).

The inlet line connection must be properly 

tightened, as possible entrance of air will cause 

cavitation.

The suction conditions can be optimized 

according to below guidelines.

2.5  General comments on

Filtration

A good filtration is vital to ensure a long and 

trouble free life of the pump.

When selecting a filter or strainer, please note 

that filter materials should be compatible with 

water, i.e. should neither corrode or dissolve. Also 

be aware of the electrochemical series of the 

applied materials.

Main filter must have a fineness of 10 μm abs.  

ß 10 >5000. The pressure loss across the filter 

should be monitored.

Water tank

Must be made of corrosion-proof material such 

as stainless steel or plastic and must be sealed to 

prevent entrance of impurities from the environ-

ment.

In smooth pipes and hoses

In 90° bends

In smooth pipes and hoses

Summary of Contents for APP 0.6

Page 1: ...APP 0 6 1 0 APP 1 5 2 5 and APP 3 0 3 5 MAKING MODERN LIVING POSSIBLE Lenntech info lenntech com Tel 31 152 610 900 www lenntech com Fax 31 152 616 289 info lenntech com Tel 31 152 610 900 www lenntec...

Page 2: ...ines for calculation of pressure losses 4 2 5 General comments on 4 3 Building up the pump unit 5 3 1 Mounting 5 3 2 Direction of rotation 5 3 3 Orientation 6 3 4 Protection from too high pressures 6...

Page 3: ...mp 2 Place the inlet filter before the tank 3 Dimension the inlet line to obtain mini mum pressure loss large flow area minimum pipe length minimum number of bends connections fittings with small pres...

Page 4: ...ng to below guidelines 2 5 General comments on Filtration A good ltration is vital to ensure a long and trouble free life of the pump When selecting a filter or strainer please note that filter materi...

Page 5: ...all to separate the inlet from the outlet end of the tank Monitoring It is recommended to continuously monitor the following conditions Water level in the tank Filter contamination Pressure inlet and...

Page 6: ...close to the pump as possible The opening characteristics of the valve must not result in peak pressures higher than 200 bar 2900 psi The valve outlet must not be connected directly to the pump suctio...

Page 7: ...ssure gauge on the high pressure side 5 3 Dry running When running the pump must always be connected to the water supply in order to avoid damage if it should run dry In systems with water tank it is...

Page 8: ...elf and there is thus no oil in the pump The pump requires no periodic replacements of seals and valve parts 6 2 Repair In case of irregular function in the pump please contact the Danfoss Sales Organ...