VLT
®
5000/5000 Flux/6000 HVAC/8000 AQUA PROFIBUS
MG.90.D1.02 – VLT is a registered Danfoss trademark
61
Parameter list
5
6
6
5
5
5
5
5
5
5
5
6
5
5
4
4
5
6
7
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
5
5
6
6
7
6
6
6
5
5
3
4
6
6
4
5
0
-1
2
0
0
0
0
0
0
0
0
2
0
-1
-3
-3
0
-3
-4
-4
-1
-4
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
-1
0
-3
0
0
-1
-2
-2
-2
-1
-2
0
0
0
-2
-2
0
0
0
P
NU Parameter
Factory setting
Range
Changes
Conversion
#
description
during
Index
operation
400
Brake function/overvoltage control
Off
Yes
No
401
Brake resistor, ohm
Depends on the unit
Yes
No
402
Brake power limit, kW
Depends on the unit
Yes
No
403
Power monitoring
On
Yes
No
404
Brake check
Off
Yes
No
405
Reset function
Manual reset
Yes
Yes
406
Automatic restart time
5 sec.
0 - 10 sec.
Yes
Yes
407
Mains Failure
No function
Yes
Yes
408
Quick discharge
Not possible
Yes
Yes
409
Trip delay torque
Off
0 - 60 sec.
Yes
Yes
410
Trip delay-inverter
Depends on type of unit
0 - 35 sec.
Yes
Yes
411
Switching frequency
Depends on type of unit
3 - 14 kHz
Yes
Yes
412
Output frequency dependent
Not possible
Yes
Yes
switching frequency
413
Overmodulation function
On
Yes
Yes
414
Minimum feedback
0.000
FB
HIGH
- 100,000.000
Yes
Yes
415
Maximum feedback
1500.000
FB
LOW
- 100,000.000
Yes
Yes
416
Process unit
%
Yes
Yes
417
Speed PID proportional gain
0.015
0.000 - 0.150
Yes
Yes
418
Speed PID integration time
8 ms
2.00 - 999.99 ms
Yes
Yes
419
Speed PID differentiation time
30 ms
0.00 - 200.00 ms
Yes
Yes
420
Speed PID diff. gain ratio
5.0
5.0 - 50.0
Yes
Yes
421
Speed PID low-pass filter
10 ms
5 - 200 ms
Yes
Yes
422
U 0 voltage at 0 Hz
20.0 V
0.0 - parameter 103
Yes
Yes
423
U 1 voltage
parameter 103
0.0 - U
VLT, MAX
Yes
Yes
424
F 1 frequency
parameter 104
0.0 - parameter 426
Yes
Yes
425
U 2 voltage
parameter 103
0.0 - U
VLT, MAX
Yes
Yes
426
F 2 frequency
parameter 104
par.424-par.428
Yes
Yes
427
U 3 voltage
parameter 103
0.0 - U
VLT, MAX
Yes
Yes
428
F 3 frequency
parameter 104
par.426 -par.430
Yes
Yes
429
U 4 voltage
parameter 103
0.0 - U
VLT, MAX
Yes
Yes
430
F 4 frequency
parameter 104
par.426-par.432
Yes
Yes
431
U 5 voltage
parameter 103
0.0 - U
VLT, MAX
Yes
Yes
432
F 5 frequency
parameter 104
par.426 - 1000 Hz
Yes
Yes
433
Torque proportional gain
100%
0 (OFF) - 500%
Yes
Yes
434
Torque integral time
0.02 sec.
0.002 - 2.000 sec.
Yes
Yes
437
Process PID Normal/inverse control
Normal
Yes
Yes
438
Process PID anti windup
On
Yes
Yes
439
Process PID start frequency
parameter 201
f
MIN
- f
MAX
Yes
Yes
440
Process PID proportional gain
0.01
0.00 - 10.00
Yes
Yes
441
Process PID integral time
9999.99 sec. (OFF)
0.01 - 9999.99 sec.
Yes
Yes
442
Process PID differentiation time
0.00 sec. (OFF)
0.00 - 10.00 sec.
Yes
Yes
443
Process PID diff. gain limit
5.0
5.0 - 50.0
Yes
Yes
444
Process PID lowpass filter time
0.01
0.01 - 10.00
Yes
Yes
445
Flying start
Disable
Yes
Yes
446
Switching pattern
SFAVM
Yes
Yes
447
Torque compensation
100%
-100 - +100%
Yes
Yes
448
Gear ratio
1
0.001 - 100.000
No
Yes
449
Friction loss
0%
0 - 50%
No
Yes
450
Mains voltage at mains fault
Depends on unit
Depends on unit
Yes
Yes
453
Speed closed loop gear ratio
1
0.01-100
No
Yes
454
Dead time compensation
ON
No
No
4-Setup
Data
type
■
Parameter list
VLT 5000