MG.90.D1.02 – VLT is a registered Danfoss trademark
46
VLT
®
5000/5000 Flux/6000 HVAC/8000 AQUA PROFIBUS
Data
type
5
6
6
5
4
4
7
7
5
6
5
3
3
3
3
6
6
6
6
6
6
6
6
6
6
4
4
4
4
■
Parameter list
VLT 6000
Conversion
index
0
-1
-1
0
-3
-3
0
0
0
-1
0
-2
-2
-2
-2
-1
0
-1
-1
-1
-1
-1
-1
-1
-1
-3
-3
-3
-3
PNU
Parameter
Factory setting
Range
Changes 4-Setup
#
description
during operation
200
Output frequency range
0 -120 Hz
0 - 1000 Hz
No
Yes
201
Output frequency low limit, f
MIN
0.0 Hz
0.0 - f
MAX
Yes
Yes
202
Output frequency high limit, f
MAX
50 Hz
f
MIN
- par. 200
Yes
Yes
203
Reference site
Hand/Auto linked reference
Yes
Yes
204
Minimum reference, Ref
MIN
0.000
0.000-par. 100
Yes
Yes
205
Maximum reference, Ref
MAX
50.000
par. 100-999.999,999 Yes
Yes
206
Ramp-up time
Depends on the unit
1 - 3600
Yes
Yes
207
Ramp-down time
Depends on the unit
1 - 3600
Yes
Yes
208
Automatic ramp-up/down
Enable
Yes
Yes
209
Jog frequency
10.0 Hz
0.0 - par. 100
Yes
Yes
210
Reference type
Sum
Yes
Yes
211
Preset reference 1
0.00 %
-100.00 - 100.00 %
Yes
Yes
212
Preset reference 2
0.00 %
-100.00 - 100.00 %
Yes
Yes
213
Preset reference 3
0.00 %
-100.00 - 100.00 %
Yes
Yes
214
Preset reference 4
0.00 %
-100,00 - 100,00 %
Yes
Yes
215
Current limit, I
LIM
1.0 x I
VLT,N
[A]
0,1-1,1 x I
VLT,N
[A]
Yes
Yes
216
Frequency bypass, bandwidth
0 Hz
0 - 100 Hz
Yes
Yes
217
Frequency bypass 1
120 Hz
0.0 - par. 200
Yes
Yes
218
Frequency bypass 2
120 Hz
0.0 - par. 200
Yes
Yes
219
Frequency bypass 3
120 Hz
0.0 - par. 200
Yes
Yes
220
Frequency bypass 4
120 Hz
0.0 - par. 200
Yes
Yes
221
Warning: Low current, I
LOW
0.0 A
0.0 - par. 222
Yes
Yes
222
Warning: High current, I
HIGH
I
VLT,MAX
Par. 221 - I
VLT,MAX
Yes
Yes
223
Warning: Low frequency, f
LOW
0.0 Hz
0.0 - par. 224
Yes
Yes
224
Warning: High frequency, f
HIGH
120.0 Hz
Par. 223 - par. 200/202 Yes
Yes
225
Warning: Low reference, Ref
LOW
-999,999.999
-999,999.999 - par. 226 Yes
Yes
226
Warning: High reference, Ref
HIGH
999,999.999
Par. 225 - 999,999.999 Yes
Yes
227
Warning: Low feedback, FB
LOW
-999,999.999
-999,999.999 - par. 228 Yes
Yes
228
Warning: High feedback, FB
HIGH
999,999.999
Par. 227 - 999,999.999 Yes
Yes
Changes during operation:
"Yes" means that the parameter can be changed,
while the VLT frequency converter is in operation.
"No" means that the VLT frequency converter must
be stopped before a change can be made.
4-Setup:
"Yes" means that the parameter can be
programmed individually in each of the four setups,
i.e. the same parameter can have four different data
values. "No" means that the data value will be the
same in all four setups.
Conversion index:
This number refers to a conversion figure to be used
when writing or reading to or from a VLT frequency
converter by means of serial communication.
Conversion index
Conversion factor
74
0.1
2
100
1
10
0
1
-1
0.1
-2
0.01
-3
0.001
-4
0.0001
Data type:
Data type shows the type and length of the
telegram.
Data type
Description
3
Integer 16
4
Integer 32
5
Unsigned 8
6
Unsigned 16
7
Unsigned 32
9
Text string
Parameter list