background image

DEVIreg™ Smart

3

Installation Guide

•  An installation wizard with room/floor type-specific 

setup (requires an app).

•  Support for multiple frame systems.

•  Compatible with several 3rd party NTC sensors.

•  Thermostat settings can be specified before instal-

lation and imported to the thermostat using a web-

generated code (For DEVIreg™ Touch), or copied 

from a thermostat in a similar installation. This 

includes DEVIreg™ Touch thermostats.

•  Smart access via app to thermostat settings after 

installation, for easy access, setup or remote trou-

bleshooting. Thermostat/timer will continuously be 

updated with newest version of software.

•  DEVIreg™ Smart can be used as a switch for On/Off 

systems

Regarding Connectivity:

•  10 smart devices (like Smartphone or Tablet) can be 

connected to 1 thermostat/switch.

•  2 smart devices can be in contact with the thermo-

stat/switch at the same time.

DEVIREG™ SMART REQUIRES WORKING Wi-Fi  

TO FUNCTION � 

Summary of Contents for 140F1143

Page 1: ...www DEVI com Installation Guide DEVIreg Smart Intelligent Electronic Timer Thermostat or Timer Switch with Wi Fi connectivity and App control...

Page 2: ...ing of the entire room and for comfort heating of the floor Among others the thermostat has the following features A touchscreen display with light An easy to follow menu driven programming and operat...

Page 3: ...at in a similar installation This includes DEVIreg Touch thermostats Smart access via app to thermostat settings after installation for easy access setup or remote trou bleshooting Thermostat timer wi...

Page 4: ...Relay Resistive load Inductive load Max 16 A 3680 W 230 V Max 1 A cos 0 3 Sensing units NTC 6 8 kOhm at 25 C NTC 10 kOhm at 25 C NTC 12 kOhm at 25 C NTC 15 kOhm at 25 C Default NTC 33 kOhm at 25 C NTC...

Page 5: ...ilt in monitoring circuit which will switch off the heating if the sensor is disconnected or short circuited Timer functions 2 periods per day for DEVIweb 5 periods per day for DEVIsmart App All clock...

Page 6: ...ral EN IEC 60730 2 7 timer EN IEC 60730 2 9 thermostat 3 Safety Instructions Make sure the mains supply to the thermostat switch is turned off before installation Important When the thermostat is used...

Page 7: ...ven supervi sion or instruction concerning use of the appliance in a safe way and understand the hazards involved by a person responsible for their safety DEVIreg Smart can modified to work as a timer...

Page 8: ...ermostat switch must be placed outside zone 2 Place it in an adjacent room and use floor sensor only Always place the thermostat switch according to local regulation on IP classes Do not place the the...

Page 9: ...floor sensor in a protecting plastic conduit in the floor construction in an appropriate place where the floor is not exposed to sunlight or draft from door openings 1 2 Equally distant and 2 cm from...

Page 10: ...maximum 0 4 Watt The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector Note Always install the floor sensor in a conduit in t...

Page 11: ...e thermostat switch 4 Add the frame before assem bling of top part to the snap locks bottom part 5 Click the front part module in place Pay attention in relation to the female header in not to bending...

Page 12: ...d reassembling the thermostat switch Press your fingers under the top of the front part and pull toward you until it releases from the snap lock To ensure that the batteries are fully charged the ther...

Page 13: ...support user interface through display and hold all the controller logic Display main functionalities are to show the current status of the thermostat switch and recognize the user actions from the b...

Page 14: ...ndication Timer switch function On Off text Symbol indications Indication Mode State Description Blue blinking Access Point Mode Thermostat switch ready for set up Blue Access Point Mode Smart phone c...

Page 15: ...utton Description Turn thermostat switch on 1 Touch any button 2 Touch control but ton 1 Thermostat switch turn on and display temperature or On Off states Turn thermostat switch off 1 Touch any butto...

Page 16: ...ivate safety lock Factory restore Touch and hold Control 1 Up 2 for 5 sec After that touch Control 1 again to confirm Activates factory restore state Away mode Touch and hold Control 1 for 1 sec to de...

Page 17: ...ed E2 Sensor short circuited Contact service The thermostat requires a restart to operate again Thermo stat over heated E3 Thermostat is overheat ed heating is turned off Wait until thermo stat cools...

Page 18: ...r Codes Communication error Nr Description Wrong SSID or password C1 STA trying to connect to the AP No IP address C2 STA connection acquired no IP yet waiting for configuration data No internet con n...

Page 19: ...ork administrator or internet service provider Identify your floor sensor type in kOhm Identify your installed output in W from label on the heating element equipment Power on the thermostat and it wi...

Page 20: ...or sen sor or a combination of room and floor sensor should be used A room only option is also available but requires that you have to break the small plastic seal and the seal in the print board belo...

Page 21: ...n connection with a wooden floor or similar material always use a floor sensor and never set the maximum floor temperature to more than 35 C Note Please contact the floor supplier before changing the...

Page 22: ...beech parquet 650 800 31 C 0 13 22 mm solid oak plank 800 32 C 0 17 Max carpet thick ness suitable for floor heating acc to EN 1307 34 C 0 18 22 mm solid fir planks 450 650 35 C IMPORTANT DURING SWIT...

Page 23: ...nfoss Danfoss shall not be liable for any consequential or inci dental damages including but not limited to damages to property or extra utility expenses No extension of the warranty period following...

Page 24: ...if Danfoss is required to inspect or repair faults that have arisen as a result of any of the above The DEVIwarranty shall not extend to products which have not been paid in full Danfoss will at all...

Page 25: ...lation Guide WARRANTY CERTIFICATE The DEVIwarranty is granted to Address Stamp Purchase date Serial number of the product Product Art No Connected output W Installation Date Signature Connection Date...

Page 26: ...EU declaration of conformity referred to in article 10 9 shall be provided as follows Hereby Danfoss A S declares that the radio equipment type i e DEVIreg Smart is in compliance with Directive 2014 5...

Page 27: ...DEVIreg Smart 27 Installation Guide 10 Disposal Instruction...

Page 28: ...DEVIreg Smart Produced by Danfoss 08 2022 08096265 AN335651484034en 010102 IMPORTER UK Danfoss Ltd 22 Wycombe End HP9 1NB GB Danfoss A S Nordborgvej 81 6430 Nordborg Syddanmark Denmark...