ENGLISH

RT 115
Application

The thermostat type 

RT 115

 is designed 

for control of forced ventilation in livestock 
buildings and hencoops. 
The thermostat has the effect of constant 
ventilation as long as the room tempera-
ture exceeds the temperature setting. 
If the room temperature is lower than the 
temperature setting, there wil only be 
intermittent ventilation. The cut-out period 
is extended when the room temperature 
falls, and if the temperature falls, and if 
the room temperature is 2 °C lower than 
the temperature setting, the thermostat 
cannot start the fan. 
The special kind of control offered by 

RT 115

 is due to the extra sensor (B) inside 

the thermostat housing. Alongside the 
sensor there is an electric heater (C) which 
is cut in when the fan is cut out, and vice 
versa.

Installation

A set of Pg13.5 cable gland is attached to 
the RT in a separate bag. To ensure IP66 

(units with automatic reset) or IP54 (units 
with external reset) grade of RT enclosure 
it is necessary to assemble this gland as 
shown in the fig. 3. If this gland is not used 
with a cable, a metal blinding should be 
also assembled.

Fitting

The thermostate should be fitted in the 
centre of the building, but in such a 
position that the body heat from the larger 
animals cannot directly influence the 
thermostat.

Setting

Set the thermostat by rotating the knob (5) 
for a temperature which is approx. 1 °C 
higher than actually desired in the building.

•  If the fan then runs continuously, the 
  capacity of the fan is to low of the 
  outdoor temperature  is too high
•  If the fan runs intermittently, the 
  plant operation should not be iterfered 
  with until  a stable room temperature is 
  reached. If the room temperature is then 
  too high or too low, resetting is done
•  If the fan does not start, the room 
  temperature is too low to permit 
 ventilation.

DANSK

RT 115
Anvendelse

Termostat type 

RT 115

 anvendes til styring 

af tvungen ventilation i stalde og hønse-
huse.
Termostaten bevirker at der ventileres 
uafbrudt sålænge rumtemperaturen er 
højere end indstil-lingstemperaturen. Er 
rumtemperaturen lavere, ventileres der 
kun periodevis. 
Udkoblingsperioden forlænges med 
faldende rumtemperatur; og er rumtem-
peraturen 2 °C lavere end indstil-lings-
temperaturen kan termostaten ikke starte 
ventilatoren.

RT 115

´s specielle styreform skyldes den 

ekstra føler (B) inden i termostathuset.
Langs føleren ligger et elvarmelegeme (C) 
der kobles ind når ventilatoren kobles ud 
og vice versa.

Montering

Et sæt Pg13,5 kabelforskruning er vedlagt
produktet i en separat pose. For at sikre
kapslingsgrad IP66 (enheder med automa-
tisk reset) eller IP54 (enheder med ekstern 
RESET) er det nødvendigt at montere

Reviews: