background image

EWT-855i

Installation Manual

Thermostat Application Guide

Description

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

Yes

Yes
Yes
Yes
Yes

No

Power Type

Hardwire - 24 VAC 

Common Wire

Table of Contents

Installation Tips

Thermostat Quick Reference

Private Label Badge

Wiring

Wiring Diagrams

Technician Setup Menu

WIFI Tech Setup

Programming

Features 

Specifications 

Page

A trained, experienced 

technician must install this 

product.

Carefully read these 

instructions.  You could damage 

this product or cause a 

hazardous condition if you fail 

to follow these instructions.

Una version en español de este 

manual se puede descargar en 

la pagina web de la compañia.

Rev. 1841

     U.S. Registered Trademark. Patents pending

Copyright      2018 All Rights Reserved.

5-7

8

13-19

2-4

Yes
Yes

20

Mount Thermostat

Align the 4 tabs on the subbase with 

corresponding slots on the back of the 

thermostat, then push gently until the 

thermostat snaps in place.

Installation Tips

Note:

 To ensure a solid fit between the 

thermostat and the subbase:

1. 

Mount subbase to a flat wall

2.

 Use screws provided

3.

 Drywall anchors should be flush with the wall

4.

 Wires should be pushed into the wall

Installation Tips

The thermostat should be installed approximately 4 to 5 feet above the 

floor.  Select an area with average temperature and good air circulation.

•  Close to hot or cold air ducts

•  That are in direct sunlight

•  With an outside wall behind the thermostat

•  In areas that do not require conditioning

•  Where there are dead spots or drafts (in corners or behind doors)

•  Where there might be concealed chimneys or pipes

Wall Locations

Pick an installation location that is easy for the user to access.  The temperature 

of the location should be representative of the building.

Installation Tip

Do not install thermostat in these locations:

Installation Tips

21-28

31

Vertical Mount

Horizontal Mount

For horizontal mount put one screw on 
the left and one screw on the right.

All of our products are mercury free. However, if the product you are 

replacing contains mercury, dispose of it properly.  Your local waste 

management authority can give you instructions on recycling and 

proper disposal.

Mercury Notice

Failure to disconnect the power before beginning to install this product 

can cause electrical shock or equipment damage.

Installation Tip: Electrical Hazard

For vertical mount put one screw on 
the top and one screw on the bottom.

Subbase Installation

11-12

9-10

29-30

MENU AUTO HEAT

Summary of Contents for EWT-855i

Page 1: ...provided 3 Drywall anchors should be flush with the wall 4 Wires should be pushed into the wall Installation Tips The thermostat should be installed approximately 4 to 5 feet above the floor Select an area with average temperature and good air circulation Close to hot or cold air ducts That are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning ...

Page 2: ... electrical shock or equipment damage Note In many heat pump systems with no emergency heat relay a jumper can be installed between E and W2 to turn thermostat into a single stage control for Emergency Heat Operation Thermostat Quick Reference Indicates the current room temperature Time and day of the week Staging Indicators Indicates stages of heat or cool running The compres sor delay feature is...

Page 3: ...or2H 1CHeatPumpSystem TypicalHeat OnlySystem TypicalHeatOnlySystemWithFan TypicalCool OnlySystem HEAT RELAY RC RH Y C W E G C R L2 L1 HOT FAN RELAY HEAT RELAY RC RH Y C W E G C R L2 L1 HOT FAN RELAY COMPRESSOR RELAY C R L2 L1 HOT RC RH Y C G Power supply Factory installed jumper Remove only when installing on 2 transformer systems Use either O or B terminals for changeover valve A24VACcommonconnec...

Page 4: ...rom OFF to 2000 hours of runtime in 50 hour increments Tech Setup Steps Room Temperature Calibration 0 F This feature allows the installer to select the minimum run time for the compressor For example a setting of 4 will force the compressor to run for at least 4 minutes every time the compressor turns on regardless of the room temperature You can set the minimum compressor run time to OFF 3 4 or ...

Page 5: ...ccupancy fan settings will energize the fan before the occupied time to provide ventilation prior to scheduled occupancy This feature only shows if the technician setup step for time periods is set to 2 Pre Occupancy Fan You can select the pre occupancy fan from OFF 1 2 or 3 hours If 1 2 or 3 is selected the fan will turn on that many hours prior to the scheduled occupied time period Tech Setup St...

Page 6: ... day s SLEEP time period To customize your 7 day Program schedule follow these steps Monday WAKE LEAVE RETURN or SLEEP Repeat steps 4 through 8 for the remaining days of the week A Note About Auto Changeover In Auto you have the ability to switch between Auto Heat or Auto Cool by pressing the system key This can be done once the current mode has reached its setpoint For example if in Auto Heat the...

Page 7: ... for any time period 1 Select HEAT or COOL with the SYSTEM key Note You have to program heat and cool each seperately 2 Press the MENU button If menu does not appear first press RUN 3 Press SCHED Note Monday is displayed and the OCCUPIED text is shown You are now programming the OCCUPIED time period for that day 4 Time is flashing Use the or key to make your time selection for that day s OCCUPIED ...

Page 8: ... replace the temporary setpoint Permanent Hold With a temporary hold set If you press the HOLD key at the bottom of your screen you will see HOLD appear below the setpoint temperature in the display The thermostat will now permanently stay at this setpoint and can be adjusted using the or keys To Return To Program Press the RUN key at the bottom of the screen to exit temporary and permanent holds ...

Reviews: