68
Fahrzeug-/Funktionsdecoder
ab Firmware-Version 1.11
68
Locomotive/Vehicle function decoder
from firmware version 3.12
CV
Name and definition
Range
Standard
131 Function mapping low beam light
(not relevant to PD*)
0 = deactivated, 1 … 28 = F1 … F28, 29 = F0 (light)
Only valid if CV137/Bit 4=1
0-29
8
132 Function mapping shunting gear
(as CV131)
0-29
4
133 Function mapping deceleration off
(as CV131)
0-29
9
134 Decision threshold for asymmetry
(see CV27)
Default value 6 corresponds approximately to 0.7 volt asymmetry and thus to the forward
voltage of a silicon diode.Values smaller 3 are not useful, values higher 6 on demand.
0-15
6
135 Multiplication speed check back signal
0 = deactivated
0-255
0
136 Division speed check back signal
0 = /1, 1 = /2, 2 = /4, 3 = /8, 4 = /16, 5 = /32, 6 = /64
0-6
0
137 Settings
Bit
Function Value
0........Unamplified function outputs instead of ZCLK and ZDAT *) .................1
1........Switch off energy saving mode .............................................................2
2........Invert SUSI driving direction *) ..............................................................4
3........Currently without function *) ...................................................................
4........Activate extended function mapping *) ...............................................16
(see CV131 and CV137/Bit 5)
5........0 = AUX3 and AUX4 on ZCLK and ZDAT *) .........................................32
1 = AUX5 and AUX6 on ZCLK and ZDAT *)
(Onlay valid if CV137/Bit 0=1)
*) (not relevant to PD*)
0-63
0