Environmental conditions
IP rating sender unit
IP54
Pollution degree
2
Temperature range
0 °C to 40 °C (32 °F to 104 °F)
Humidity (rel.)
80% up to 31 °C/87.8 °F
Linear decrease to 50% @40 °C/104 °F
Altitude max:
2000 m/6562 ft
Power supply
Meter unit
6 x AA
Alkaline batteries - 9 VDC
Sender unit (single operation)
Derived from meter unit - 9 VDC
Sender unit (remote operation - OCA)
Power Over Ethernet (ETH/POE)
POE standard specification
IEEE802.3at or IEEE802.3af
No passive injector devices or switches must be used!
Laser specification
Complies with 21 CFR 1040 with deviations pursuant to Laser Notice 50,
and with IEC/EN 60825-1 (2001)
Laser
Class 3R laser product
Wavelength
532 nm
Max power:
less than 5 mW
Dimensions and weights
Meter unit
W x H x D: 85 x 45 x 160 mm / 405 g (0.9 lb)
Sender unit
W x H x D: 48 x 44 x 120 mm / 295 g (0.65 lb)
Inclinometer system
Measuring range
±45° @ ±0.1° (full accuracy)
±90° @ ±1° (reduced accuracy)
Thermometer/Hygrometer (Sensor)
Range/Accuracy
0 to 40 °C (32 to 104 °F) /
±
2 °C (35.6 °F)
10 ... 100% (rel.) /
±
5 %
Connections
Meter unit
etherCON (RS232 - 19.2 kB/s)
Sender unit
POE enabled etherCON (RS232/Ethernet)
RS232: 19.2 kB/s
Ethernet (OCA): 100 Mbit/Half-duplex
Cable type
Shielded CAT5e 1:1 cable
Cable length
RS232: Up to 30 m (100 ft)
Ethernet (OCA): Up to 100 m (328 ft)
Controls and indicators (Meter unit)
2 x Soft keys
Switch on/off, access MENU and LASER
Display
Graphical LC display with backlight
2 Technical specifications
d&b ArraySight Manual 1.7 en