4.1 Resetting the angle (zeroing)
Preparation
1. With the flying frame resting on a solid, stable and flat
surface, check the sender unit is correctly aligned.
2. Place a good quality spirit level, or calibrated digital level on
the top edge of the flying frame as shown in the graphic
opposite. You need to check that the top of the flying frame is
truly horizontally
[x] and vertically [z] leveled.
3. Fix the flying frame at the front or rear as required to ensure
that it is perfectly aligned.
↳Once this is achieved, you can reset the angle of the
sender unit as follows:
Resetting the angle
1. Switch on the connected meter unit and confirm that the initial
display is showing
0.0°.
2. Select "«MENU»
Þ
«Sender settings»
Þ
«Reset angle»".
3. Press «SET» to confirm the reset.
↳The angle displayed, will be set to zero (0.0°) and the
offset value is stored in the sender unit, even when it is
disconnected from the meter unit.
Note: The angle needs to be reset for each sender unit in
use. If you have sender units attached to a left and right array,
when you plug the second sender unit in, you will need to
reset this to zero, but if subsequently you reconnect the meter
unit to the first sender unit at this location, the offset value
stored in the sender unit is still valid.