1.1 Scope of supply
Before setting up the system, please verify the shipment for
completeness and proper condition of the items.
If there is any sign of obvious damage, do not operate the units
and contact your local dealer from whom you received the system.
Pos. Qty. d&b Code
Description
1
Z5710
d&b ArraySight set
Including:
[1]
2
Z5711
ArraySight sender unit
[2]
2
2 x Fixing screws for each
sender unit
(Torx T20, M4 x 14 mm).
[3]
1
Z5712
ArraySight meter unit
[4]
2
K6006.200.00
Shielded CAT5e 1:1 cable,
30 m (100 ft)
[5]
1
D2735.EN .01
ArraySight Manual
1.2 Intended use
The d&b ArraySight laser inclinometer system is intended to
vertically aim an entire array in its operating position. It provides
precision angle measurement over a wide measuring range of ±90
degrees. The sender unit uses a 3-axis MEMS accelerometer for
data acquisition. This provides accurate tilt sensing over one axis,
even when the unit is tilted on another axis. Accurate angle
measurements can be achieved, resolved to ±0.1 degrees on the
display of the meter unit.
The compact sender unit is housed in a weather resistant enclosure.
It utilizes an ultra bright green laser to provide a visible indication
for aiming the array, with a flashing mode to help locate the beam
in bright surroundings.
The sender unit can be attached to dedicated d&b Flying frames.
For this purpose, the sender unit has two threaded inserts on its
base and comes with dedicated fixing screws (Torx T20, M4 x
14 mm).
Easy calibration
Multiple sender units can be used with one meter unit. Calibration
information is stored in the sender unit using non-volatile memory,
so it remains accurate after the meter unit is disconnected. Sender
units can be reset on the fly to any angle within range, allowing
adjustment of system elevation to be made in absolute values if
required. Calibration is carried out via the meter unit’s onscreen
menu, without the need to dismantle units or use precision
hardware.
Relative angle measurement
The meter unit’s zero function means relative angle measurements
can be made via the on-screen menu and the last four readings are
stored for easy recall.
1 d&b ArraySight
d&b ArraySight Manual 1.7 en
5