3.5.4 Sender settings
IP
settings
Defines the required IP settings such as the IP
address
Þ
«IP», the Subnet
Þ
«SN», the Gateway
Þ
«GW» and the IP mode
Þ
«Mode».
By factory default, the IP mode is set to «Auto» and
is recommended for a network with a DHCP server
present
Þ
DHCP+LL (Link Local).
The IP mode can be set to «Manual» if required.
Remote
ID
Defines the required «Remote ID» settings in
connection with d&b R1.
The «Remote ID» menu comprises two items, the
«Subnet» and the «Device ID».
Within an d&b OCA network, up to 100 subnets
can be defined (values 0 to 99).
Using the two digit Device ID for each subnet, you
can define a total of 63 devices (values 1 to 63).
Reset
angle
(zeroing)
Saves an angle offset in the sender unit for relative
measurements. When performed, the meter displays
zero, when the sender unit is in its current position.
The reset angle function is also used to ensure that
the sender unit is correctly aligned to the flying
Chapter 4.1 "Resetting the angle
Calibrate
By factory default, the sender unit is already
calibrated.
However, for maintenance reasons it might be
necessary to re-calibrate the sender unit’s
accelerometer.
For this purpose, selecting «Calibrate» starts the
calibration procedure for the connected sender unit
as described in
d&b ArraySight Manual 1.7 en