NOTICE!
Potential risk of malfunction and/or damage to the
device!
Only use POE injector devices and/or switches which comply with
the POE standards
IEEE802.3at or IEEE802.3af.
DO NOT use passive injector devices or switches.
The data transmission rate is fixed @ 100 Mbit/Half-duplex.
Therefore ensure that you use compatible switches.
In standard operation, the sender unit is directly connected to the
meter unit which provides power supply and communication via its
RS232 interface.
However, the sender unit also supports the d&b OCA/AES70
protocol and therefore directly integrates into the d&b workflow in
connection with the d&b ArrayCalc simulation and R1 Remote
control software. This allows multiple sender units to be read out
within R1.
By factory default, the sender unit comes with the following
ethernet and remote settings:
IP mode:
IP address:
Subnet:
Gateway:
Remote ID:
Auto
Þ
DHCP+LL (Link Local)
192.168.0.111
255.255.255.0
192.168.0.1
0.01