8.11.9
ROD (AquadB) 5V (X5)
A 5V incremental encoder (AquadB) can be used as standard motor feedback (primary
and secondary,
ð
p.52). The thermostat contact in the motor is connected to X1.
Every time the 24V auxiliary voltage is switched on, the amplifier need start-up informa-
tion for the position controller (parameter value MPHASE). Depending on the feedback
type either wake&shake is executed or the value for MPHASE is read out of the ampli-
fier's EEPROM.
If lead lengths of more than 50m are planned please consult our customer service.
Frequency limit (A, B, N): 1.5 MHz
Type
FBTYPE
Up
Remarks
ROD (AquadB) 5V
13
5V +/-5%
MPHASE from EEPROM
ROD (AquadB) 5V
19
5V +/-5%
MPHASE from wake & shake
Don't use this feedback type with vertical load (hanging load).
SERVOSTAR
®
300 Product Manual
61
Danaher Motion
10/2007
Electrical installation
SERVOSTAR 300