6.2
Technical data
6.2.1
Technical data for 110/230 V (types S3_ _6_)
SERVOSTAR
Electrical data
DIM
303
306
310
Order Code
—
S30361
S30661
S31061
Rated supply voltage
(grounded supply, phase to phase)
V~
1 x 110V
-10%
… 1 x 230V
+10%
3 x 110V
-10%
… 3 x 230V
+10%
50/60 Hz
Rated input power for S1 operation
kVA
1.1
2.4
4
Max. DC bus link voltage
V=
450
Rated output current (rms value,
±
3%)
at 1x115V
Arms
3*
3*
3*
at 3x115V
Arms
3.5
8
10
at 3x230V
Arms
3
6
10
at 1x230V
Arms
3*
4*
4*
Peak output current (rated current x 2 for approx. 5s,
±
3%)
at 1x115V
Arms
5*
5*
5*
at 3x115V
Arms
9
15
20
at 3x230V
Arms
9
15
20
at 1x230V
Arms
9*
9*
9*
Switching frequency of the output stage
kHz
8 (16**)
Technical data for regen circuit
—
ð
Threshold for overvoltage switch-off
at 115V
VDC
235
at 230V
VDC
455
Motor inductance min.
at 1x115V
mH
3.7
3.7
3.7
at 3x115V
mH
2.1
1.3
1.0
at 3x230V
mH
4.3
2.6
1.9
at 1x230V
mH
4.3
4.3
4.3
Motor inductance max.
mH
Consult our customer support
Form factor of the output current
(rated conditions, min. load inductance)
—
1.01
Bandwidth of current controller
kHz
> 1.2
Residual voltage drop at rated current
V
4
Thermal dissipation, output stage disabled
W
12
Thermal dissipation at rated current
(incl. PSU losses, without regen dissipation)
W
35
60
90
Mechanical data
Weight
kg
approx. 2.6
Height, without connectors
mm
275
279
Width
mm
70
Depth, without connectors
mm
171
Depth, with connectors
mm
< 200
*
in single-phase applications nom./peak current is limited to value below nominal
value dependent on the motor constant Kt and the motor speed.
**
at reduced current (50%)
18
SERVOSTAR
®
300 Product Manual
Technical description
10/2007
Danaher Motion