131
Service Codes
Are all
of the phases connected
correctly according to the phase cable
configurations (Standard or Reverse)
and in line with the MCU
« PhaseCableReversed »
parameter ?
Correct the issue on the
« PhaseCableReversed » parameter and /
or on any phase not correctly connected?
(MCU and motor).
Are all
motor phase resistance
measurements
Access to the motor phase connection point by opening the motor
phase panel, blanket or by removing the motor phase POC.
With an ohmmeter measure that the motor phase resistances
between phases of the same group return a low resistance value.
Group 1 (phase A1, B1 & C1)
–
phases motor type
Group 2 (Phase A2, B2 & C2)
–
phases motor type
Group 3 (Phase A3, B3 & C3)
–
phases motor type
Defective motor.
Replace motor.
No
C
Close the motor
phase panel or
blanket or reconnect
the motor phase POC.
Yes
Complete
Perform a road test to check
further error occurrences of
the original error code.
Wait for 10 minutes before
taking any further action.
Yes
Turn ignition ON.
E
Connect to the MCU with
ODIN and check the SysFile.
Does the same
SysFile ID occur
again?
No
D
Yes
Switch OFF the auxiliary
batteries switch.
Ensure all High Voltage
Electrical sources are
switched OFF.
Switch ON the auxiliary
batteries switch.
Refer to the Dana TM4 Product
installation guide and operation and
maintenance manual for more details
on the phase cables configurations
and parameter setting
Refer to the motor installation guide for more
details on installation and deinstallation
procedure including safety warning
considerations
No
Summary of Contents for SPICER TM4 SUMO HP HV Powertrain
Page 1: ...1 Dana TM4 SUMO HP HV Powertrain Troubleshooting Guide SMTS 0603 March 2022 ...
Page 9: ...9 General Information Dana TM4 Motor and MCU Components Example Dana TM4 Motor Dana TM4 MCU ...
Page 14: ...14 General Information Motor connector head Identification Dana TM4 MCU A3 Dana TM4 Motor ...
Page 36: ...36 Service Codes ...
Page 38: ...38 Service Codes ...
Page 41: ...41 Service Codes Connector type 2 pinout Connector type 1 pinout ...
Page 47: ...47 Service Codes Connector type 2 pinout Connector type 1 pinout ...
Page 51: ...51 Service Codes Motor internal resistance measurement table ...
Page 53: ...53 Service Codes ...
Page 54: ...54 Service Codes ...
Page 55: ...55 Service Codes ...
Page 57: ...57 Service Codes ...
Page 62: ...62 Service Codes Connector type 2 pinout ...
Page 63: ...63 Service Codes ...
Page 64: ...64 Service Codes ...
Page 67: ...67 Service Codes Connector type 2 pinout ...
Page 68: ...68 Service Codes ...
Page 69: ...69 Service Codes ...
Page 71: ...71 Service Codes ...
Page 72: ...72 Service Codes ...
Page 73: ...73 Service Codes ...
Page 76: ...76 Service Codes ...
Page 77: ...77 Service Codes ...
Page 79: ...79 Service Codes ...
Page 85: ...85 Service Codes ...
Page 87: ...87 Service Codes ...
Page 89: ...89 Service Codes ...
Page 91: ...91 Service Codes ...
Page 105: ...105 Service Codes ...
Page 107: ...107 Service Codes ...
Page 109: ...109 Service Codes ...
Page 111: ...111 Service Codes ...
Page 113: ...113 Service Codes ...
Page 115: ...115 Service Codes ...
Page 117: ...117 Service Codes ...
Page 122: ...122 Service Codes ...
Page 125: ...125 Service Codes References ...
Page 145: ...145 Service Codes ...
Page 146: ...146 Service Codes ...
Page 147: ...147 Service Codes ...
Page 148: ...148 Service Codes ...
Page 150: ...150 Service Codes ...
Page 152: ...152 Service Codes ...
Page 158: ...158 Service Codes ...
Page 160: ...160 Service Codes ...