Version
Document
Lang.
Page
16.06.2021
3050-3056 BJÖRK touch-free dispenser, soap / disinfectant
Maintenance and service manual
ENG
6
of 12
DAN DRYER A/S • Alsikevej 8 • DK-8920 Randers NV • +45 86 41 57 11 • www.dandryer.com • [email protected]
1. Connect the transformer to the pump hou-
sing.
2. The cable can be passed through the bot-
tom of the front cover or through the hole in
the rear panel.
3. Make sure that the cable is not pinched
when the front cover is opened and closed.
4. Connect the transformer to a 230 V power
outlet.
Do not install batteries if you have chosen to
use the external power supply.
External power supply (optional):
Rear hole
for cable
Bottom hole
for cable