3050-3056 BJÖRK touch-free dispenser, soap / disinfectant

Maintenance and service manual

ENG

of 12

DAN DRYER A/S • Alsikevej 8 • DK-8920 Randers NV • +45 86 41 57 11 • www.dandryer.com • [email protected]

7.  Mount the liquid 

container by 
gently pushing it 
into the groove 
on the pump 
housing.

8.  Pull the silicone tube downwards and place the 

outlet nozzle in the slot. Make sure that the collar 
is located 

under

 the pump housing.

If the outlet nozzle 
is placed or instal-
led incorrectly, the 
pump will not func-
tion or its function 
will be decreased.

Make sure that the
collar is located 

under

the pump housing.

9.  Close the fl ap on the front of the pump 

housing by turning clockwise and lifting it 
approximately 1 cm so the two pins fall into 
the guide holes.

11.  Open the door to the battery box.

(If you have chosen to use external power 
supply, skip to page 6).

10.  Remove the 

protective 
plastic plug.

Installation and connection (continued):

Summary of Contents for 3050

Page 1: ...ctant Maintenance and service manual ENG 1 of 12 DAN DRYER A S Alsikevej 8 DK 8920 Randers NV 45 86 41 57 11 www dandryer com info dandryer dk 3050 3056 BJÖRK touch free dispenser liquid soap disinfectant Maintenance and service manual Version Description of changes Page s Version history ...

Page 2: ...st have read and understood this manual If you have questions concerning the use or main tenance of your dispenser you are welcome to contact us Intended product use The dispenser is designed for installation in indo or public or private restrooms and may only be used for liquid soap disinfectant The supplier s product liability DAN DRYER A S accepts no responsibility if the dispenser is installed...

Page 3: ...l at the chosen location by using the enclosed mounting template 3 Remove the liquid container by gently pul ling it out of the pump housing To prevent accidental activation the dispen ser must be placed at least 200 mm above the tabletop with normal reflection If the worktop is made of stainless steel or other reflective material the minimum distance is 300 mm 01 2 3 4 5 46 7 89 4 9 9 4 6 6 6 7 7 2...

Page 4: ...zzle in the slot Make sure that the collar is located under the pump housing If the outlet nozzle is placed or instal led incorrectly the pump will not func tion or its function will be decreased Make sure that the collar is located under the pump housing 9 Close the flap on the front of the pump housing by turning clockwise and lifting it approximately 1 cm so the two pins fall into the guide hole...

Page 5: ...onnection continued 12 Carefully remove the battery box from the pump housing Be careful not to pull the wires Mount four AA batteries as shown Be aware that they must be properly oriented with polarity as indica ted inside the battery box 13 Put the battery box back into the pump housing and gently close the door to the battery box 14 Close the front cover by pushing it against the wall until you...

Page 6: ... Connect the transformer to the pump hou sing 2 The cable can be passed through the bot tom of the front cover or through the hole in the rear panel 3 Make sure that the cable is not pinched when the front cover is opened and closed 4 Connect the transformer to a 230 V power outlet Do not install batteries if you have chosen to use the external power supply External power supply optional Rear hole...

Page 7: ...the cap and wipe any spilled soap 1 Open the front cover using the supplied square key 2 Open the flap on the front of the pump hou sing by gently lifting it approximately 1 cm and turn it anticlockwise 3 Remove the liquid container by gently pul ling it out of the pump housing See next page for further instructions 5 Mount the liquid container by gently pushing it into the groove on the pump housi...

Page 8: ... on the front of the pump housing by turning clockwise and lifting it approximately 1 cm so the two pins fall into the guide holes 6 continued Liquid filling Make sure that the collar is located under the pump housing 8 Close the front cover by pushing it against the wall until your hear a click The dispenser is now ready for use If the outlet nozzle is placed or installed incorrectly the pump will...

Page 9: ...box 1 Open the front cover using the supplied square key 3 Carefully remove the battery box from the pump housing Be careful not to pull the wires Replace the four AA batteries Be aware that they must be properly oriented with polarity as indicated inside the battery box 4 Put the battery box back into the pump housing and gently close the door to the battery box 5 Close the front cover by pushing...

Page 10: ...ge the batteries If none of the above actions correct the problem the pump housing must be replaced NOTE THAT THE DISPENSER ONLY WORKS WITH CLOSED FRONT COVER The dispenser works but no soap disinfectant is delivered Pump function can be heard Make sure that the container is not empty Check that the outlet nozzle is mounted correctly as illustrated in the chapter Liquid filling Check that the outle...

Page 11: ...oap disinfectant Maintenance and service manual ENG 11 of 12 DAN DRYER A S Alsikevej 8 DK 8920 Randers NV 45 86 41 57 11 www dandryer com info dandryer dk Technical specifications Power supply 4 x AA batteries Optional power supply Transformer 100 240V 50 60 0 5A IP20 Dimensions ...

Page 12: ... Product name Article No 1 Transformer 230V 10888 Transformer 230V UK 10894 Transformer 110V 10889 2 Lock housing 28200 3 Insert for lock housing 28201 4 Key square 8 mm 28202 5 Lock pawl 33715 6 Spring for lock 33725 7 Wall fixture 10846 8 Cabinet white 50750 Cabinet black 50756 9 Top plate 6 variants 3090 3092 3096 3101 3102 3103 10 Pump housing 10920 11 Extractor 10925 12 Liquid container 10836 ...

Reviews: