Preface  

 

 

 

2

General  

 

 

 

2

Intended product use 

 

 

2

The supplier’s product liability 

 

2

Safety and warnings 

 

 

2

Installation and connection 

 

3

External power supply (optional)  

6

Liquid fi lling 

 

 

 

7

Battery exchange 

 

 

9

Regular maintenance 

 

 

10

Trouble shooting 

 

 

10

Technical specifi cations  

 

11

Dimensions 

 

 

 

11

Spare parts 

 

 

 

12

Table of contents:

Preface

Thank you for purchasing your equipment from 
DAN DRYER A/S and congratulations on your 
new soap/disinfectant dispenser. If you use and 
maintain your dispenser according to our manu-
al, it will work to your satisfaction for many years.

General

The dispenser must only be installed and used 
in accordance with these instructions and safety 
precautions. All service staff  who work with 
installation, servicing and repair of the dispenser 
must have read and understood this manual. If 
you have questions concerning the use or main-
tenance of your dispenser, you are welcome to 
contact us.

Intended product use

The dispenser is designed for installation in indo-
or public or private restrooms and may only be 
used for liquid soap/disinfectant.

The supplier’s product liability

DAN DRYER A/S accepts no responsibility if the 
dispenser  is installed, used, modifi ed or compo-
sed otherwise than specifi ed in this manual.

Warning!

If the dispenser is not installed and connected 
properly it can be dangerous to use due to the 
risk of electric shock. Always follow the installa-
tion instructions in this manual.
All service staff  who work with servicing and 
repairing of the dispenser must have read and 
understood this manual.

Warning!

During cleaning, inspection, service etc. the 
dispenser must always be disconnected from 
the main power supply.

Safety precautions:

Maintenance work requiring dismantling of the 
dispenser must only be carried out by staff  with 
proper training.

Safety precautions:

Check before use that:
•  the dispenser is securely attached to the wall.
•  the dispenser is properly cleaned.
•  the dispenser is not damaged or otherwise in 

disorder.

Summary of Contents for 3050

Page 1: ...ctant Maintenance and service manual ENG 1 of 12 DAN DRYER A S Alsikevej 8 DK 8920 Randers NV 45 86 41 57 11 www dandryer com info dandryer dk 3050 3056 BJÖRK touch free dispenser liquid soap disinfectant Maintenance and service manual Version Description of changes Page s Version history ...

Page 2: ...st have read and understood this manual If you have questions concerning the use or main tenance of your dispenser you are welcome to contact us Intended product use The dispenser is designed for installation in indo or public or private restrooms and may only be used for liquid soap disinfectant The supplier s product liability DAN DRYER A S accepts no responsibility if the dispenser is installed...

Page 3: ...l at the chosen location by using the enclosed mounting template 3 Remove the liquid container by gently pul ling it out of the pump housing To prevent accidental activation the dispen ser must be placed at least 200 mm above the tabletop with normal reflection If the worktop is made of stainless steel or other reflective material the minimum distance is 300 mm 01 2 3 4 5 46 7 89 4 9 9 4 6 6 6 7 7 2...

Page 4: ...zzle in the slot Make sure that the collar is located under the pump housing If the outlet nozzle is placed or instal led incorrectly the pump will not func tion or its function will be decreased Make sure that the collar is located under the pump housing 9 Close the flap on the front of the pump housing by turning clockwise and lifting it approximately 1 cm so the two pins fall into the guide hole...

Page 5: ...onnection continued 12 Carefully remove the battery box from the pump housing Be careful not to pull the wires Mount four AA batteries as shown Be aware that they must be properly oriented with polarity as indica ted inside the battery box 13 Put the battery box back into the pump housing and gently close the door to the battery box 14 Close the front cover by pushing it against the wall until you...

Page 6: ... Connect the transformer to the pump hou sing 2 The cable can be passed through the bot tom of the front cover or through the hole in the rear panel 3 Make sure that the cable is not pinched when the front cover is opened and closed 4 Connect the transformer to a 230 V power outlet Do not install batteries if you have chosen to use the external power supply External power supply optional Rear hole...

Page 7: ...the cap and wipe any spilled soap 1 Open the front cover using the supplied square key 2 Open the flap on the front of the pump hou sing by gently lifting it approximately 1 cm and turn it anticlockwise 3 Remove the liquid container by gently pul ling it out of the pump housing See next page for further instructions 5 Mount the liquid container by gently pushing it into the groove on the pump housi...

Page 8: ... on the front of the pump housing by turning clockwise and lifting it approximately 1 cm so the two pins fall into the guide holes 6 continued Liquid filling Make sure that the collar is located under the pump housing 8 Close the front cover by pushing it against the wall until your hear a click The dispenser is now ready for use If the outlet nozzle is placed or installed incorrectly the pump will...

Page 9: ...box 1 Open the front cover using the supplied square key 3 Carefully remove the battery box from the pump housing Be careful not to pull the wires Replace the four AA batteries Be aware that they must be properly oriented with polarity as indicated inside the battery box 4 Put the battery box back into the pump housing and gently close the door to the battery box 5 Close the front cover by pushing...

Page 10: ...ge the batteries If none of the above actions correct the problem the pump housing must be replaced NOTE THAT THE DISPENSER ONLY WORKS WITH CLOSED FRONT COVER The dispenser works but no soap disinfectant is delivered Pump function can be heard Make sure that the container is not empty Check that the outlet nozzle is mounted correctly as illustrated in the chapter Liquid filling Check that the outle...

Page 11: ...oap disinfectant Maintenance and service manual ENG 11 of 12 DAN DRYER A S Alsikevej 8 DK 8920 Randers NV 45 86 41 57 11 www dandryer com info dandryer dk Technical specifications Power supply 4 x AA batteries Optional power supply Transformer 100 240V 50 60 0 5A IP20 Dimensions ...

Page 12: ... Product name Article No 1 Transformer 230V 10888 Transformer 230V UK 10894 Transformer 110V 10889 2 Lock housing 28200 3 Insert for lock housing 28201 4 Key square 8 mm 28202 5 Lock pawl 33715 6 Spring for lock 33725 7 Wall fixture 10846 8 Cabinet white 50750 Cabinet black 50756 9 Top plate 6 variants 3090 3092 3096 3101 3102 3103 10 Pump housing 10920 11 Extractor 10925 12 Liquid container 10836 ...