background image

Rev. 1.0.1 | © 2018 Dallmeier | www.dallmeier.com 

39

Commissioning MDF5400HD-DN

 

Observe the chapter “Pin Assignment” on page 42.

 

Connect the required cables to the relevant interfaces of the encoder unit.

The orientation of your device’s RJ45 jack may differ from the figure previously shown.

LAN / PoE (RJ45 jack, PoE conformity IEEE 802.3af)

Video preview output (HDMI

*)

 Micro port – Type D)

Memory card slot (microSDXC

*)

 compatible)

Power IN (Weidmüller male connector SL 3.50/02/90G)

Audio Line IN (3.5 mm phone jack, for stereo TRS plug)

Audio Line OUT (3.5 mm phone jack, for stereo TRS plug)

Summary of Contents for MDF5400HD-DN

Page 1: ...006834 Rev 1 0 1 2018 12 19 English MDF5400HD DN Commissioning...

Page 2: ...View California USA HDMI of HDMI Licensing LLC headquartered in Sunnyvale California USA JavaScript of Oracle Corporation and or its affiliates headquartered in Redwood Shores California USA microSDXC...

Page 3: ...s 11 Scope of Delivery 11 Transportation and Packaging 11 Warranty 11 Appropriate Use 12 Operation 13 Approvals Certifications 13 6 Requirements 14 Ambient Conditions 14 Power Supply 15 7 Maintenance...

Page 4: ...oduct documentation for the device carefully and thoroughly before using the device Always observe and follow the contained instructions notes and warnings as well as the technical data in the current...

Page 5: ...eristics of the device The target audience of the document is trained system integrators video security surveillance systems installation contractors Configuration The document entitled Configuration...

Page 6: ...ult in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not...

Page 7: ...ry out instructions one after the other in the sequence described Expressions in quotation marks usually refer to individual components of the device housing parts mounting elements connections interf...

Page 8: ...cal appliances Periodic inspection on electrical appliances General requirements for electrical safety Regulations The use of video and audio security surveillance systems is in general strictly regul...

Page 9: ...ironment resulting condensation may cause malfunctions and damage In this case wait until the device has reached room temperature up to 8 hours before commissioning Earthing Equipotential Bonding For...

Page 10: ...vice from the PoE enabled PSE port Contact the sales partner responsible for your area Burnt Smell from the Device If you notice burnt smell or a formation of smoke coming from the device immediately...

Page 11: ...n DVD ROM Product documentation published in print and or on DVD ROM The scope of delivery may differ depending on the ordered equipment device variant or country of destination Transportation and Pac...

Page 12: ...compact dome housing the connected encoder unit into a separate box housing The device is designed for indoor installations in suspended ceilings and can be operated with Power over Ethernet PoE Class...

Page 13: ...Poor lighting can lead to an incorrect white balance Approvals Certifications The following approvals certifications were valid for the device at the time of this document s compilation CE FCC RCM UL...

Page 14: ...light high heat radiation e g radiator improper ambient temperatures nearby strong radiation sources e g radio transmitters magnetic fields corrosive gases and liquids e g salt water insufficient air...

Page 15: ...t grounding earthing of the device in accordance with the currently applicable DIN VDE and ISO standards in order to ensure the safety of persons protection against dangerous contact voltages NOTICE D...

Page 16: ...e and therefore the intensity of the electric field between the contacts rises sharply when un mating the jack plug connection The more un mating cycles are carried out under PoE load the higher the l...

Page 17: ...the device due to improper cleaning practices Clean the housing outside with a clean soft dry and antistatic cloth Do not use detergents Damage to the lens element due to improper cleaning practices...

Page 18: ...rilling template with markings for the intended installation hole 70mm and the required drill holes 5mm when using anchors dowels Tool e g center punch or awl for marking drill hole locations through...

Page 19: ...Rev 1 0 1 2018 Dallmeier www dallmeier com 19 Commissioning MDF5400HD DN A 20 30 B t 9mm or t 18mm t 9 18mm Suspended Ceiling Panel Thickness t...

Page 20: ...with hole saw or a drywall utility saw When using an electrically powered jigsaw or a hand saw you should first draw a circle line with a radius of 35mm around the center point to ensure the specified...

Page 21: ...MDF5400HD DN Unscrew the housing ring counterclockwise from the dome housing If necessary use the provided hand tool as shown above to loosen the screw connection more easily NOTICE When using the pro...

Page 22: ...ssary use a small slotted screwdriver or similar to lift out the plastic cap at one of its notches as shown above NOTICE Proceed with caution when lifting out the plastic cap with a screwdriver Be car...

Page 23: ...ssioning MDF5400HD DN Pass the encoder unit through the ceiling panel and insert the dome housing into the installation hole Before inserting the dome housing make sure that both retaining wings are s...

Page 24: ...the dome housing in the ceiling panel To do this tighten the Phillips PH1 screw of both retaining wings with a suitable screwdriver in clockwise direction until both retaining wings swivel out and th...

Page 25: ...llmeier com 25 Commissioning MDF5400HD DN When removing the device at a later date the retaining wings on the dome housing must be swiveled back to their default position by simply turn ing the corres...

Page 26: ...ier www dallmeier com MDF5400HD DN Commissioning A Reinsert the plastic cap back to its original position in the dome housing When doing so ensure that the cylindrical mount for the ambient light sens...

Page 27: ...oning MDF5400HD DN A Screw the housing ring in clockwise direction back onto the dome housing as far as it will go Use the provided hand tool as shown above to tighten the housing ring NOTICE Be caref...

Page 28: ...panel using 4 suitable screws e g chipboard screws with a diameter of 3 5mm so that the encoder unit is secured against slipping e g when replacing the ceiling panel NOTICE Pay attention to the suita...

Page 29: ...mmissioning MDF5400HD DN A Observe the chapter Interfaces on page 38 Connect the required cables and finally establish the power supply via PoE or by an external power supply unit The device starts up...

Page 30: ...1 0 1 2018 Dallmeier www dallmeier com MDF5400HD DN Commissioning 5mm 3 70mm B The drilling cutting entry point should always be on the later visible side of the ceiling panel Panel thickness t 9mm or...

Page 31: ...e Remove the drilling template from the ceiling panel Cut the installation hole with a diameter of exactly 70mm into the ceiling panel using a suitable tool e g a drilling machine with hole saw or a d...

Page 32: ...ommissioning Unscrew the housing ring counterclockwise from the dome housing If necessary use the provided hand tool as shown above to loosen the screw connection more easily NOTICE When using the pro...

Page 33: ...through the ceiling panel and insert the dome housing into the installation hole insert suitable anchors dowels into the existing drill holes beforehand if applicable Before inserting the dome housin...

Page 34: ...34 Rev 1 0 1 2018 Dallmeier www dallmeier com MDF5400HD DN Commissioning B Fix the dome housing with three suitable screws e g chipboard screws with a diameter of 3 4mm in the ceiling panel...

Page 35: ...oning MDF5400HD DN B Screw the housing ring in clockwise direction back onto the dome housing as far as it will go Use the provided hand tool as shown above to tighten the housing ring NOTICE Be caref...

Page 36: ...panel using 4 suitable screws e g chipboard screws with a diameter of 3 5mm so that the encoder unit is secured against slipping e g when replacing the ceiling panel NOTICE Pay attention to the suita...

Page 37: ...mmissioning MDF5400HD DN B Observe the chapter Interfaces on page 38 Connect the required cables and finally establish the power supply via PoE or by an external power supply unit The device starts up...

Page 38: ...38 Rev 1 0 1 2018 Dallmeier www dallmeier com MDF5400HD DN Commissioning 9 Interfaces...

Page 39: ...encoder unit The orientation of your device s RJ45 jack may differ from the figure previously shown LAN PoE RJ45 jack PoE conformity IEEE 802 3af Video preview output HDMI Micro port Type D Memory car...

Page 40: ...40 Rev 1 0 1 2018 Dallmeier www dallmeier com MDF5400HD DN Commissioning 10 Inserting a Memory Card microSDXC card optional...

Page 41: ...mage to the device or memory card due to incorrect card insertion Make sure that the contacts of the used memory card are facing forward and upwards when inserting it into the memory card slot of the...

Page 42: ...nel Left channel Ring Right channel Right channel Sleeve Ground Ground 11 Pin Assignment Audio Line IN Line OUT each 3 5 mm phone jack for stereo TRS plug Audio Line OUT stereo Output level at 10k loa...

Page 43: ...wer IN Weidm ller male connector SL 3 50 02 90G mating connector Weidm ller plug in connector BL 3 50 02 180 SN Power IN NOTICE Damage to the device due to improper power supply Damage to electronic c...

Page 44: ...device with Power over Ethernet in this case a single port PoE injector is additionally required To configure the device the client PC must meet the following system requirements System Requirements O...

Page 45: ...r can establish an Ethernet connection to the device if necessary contact your network administrator for more information and assistance Start the web browser Enter the IP address of the device into t...

Page 46: ...administrator account are User name admin Password 3 NOTICE Risk of unauthorized access to the device and intentional misuse of the system Change the default login credentials of the administrator acc...

Page 47: ...evel max 2 83Vp p Input impedance 29k Audio Line OUT stereo 1 3 5mm phone jack for stereo TRS plug Output level at 10k load max 3 11Vp p Output impedance 320 Ethernet 1 RJ45 jack female connector 10BA...

Page 48: ...sions Approx 95 H49mm dome housing with lens sensor unit Approx W62 H42 D115mm encoder unit Cable length Approx 160mm between dome housing and encoder unit Weight Approx 270g dome housing with lens se...

Page 49: ...Type CE FCC RCM UL DIN 50130 4 compliant The technical product specification basic data in this document is based on the information at the time of this document s compilation Detailed information an...

Page 50: ...50 Rev 1 0 1 2018 Dallmeier www dallmeier com MDF5400HD DN Commissioning 14 Dimensions 70mm 23mm 94 60mm 37 48mm 37 10mm 48 76mm Max 18mm Min 9mm...

Page 51: ...Rev 1 0 1 2018 Dallmeier www dallmeier com 51 Commissioning MDF5400HD DN 62mm 57mm 57mm 115mm 5mm R 1 7 5 m m 12 50mm 32mm 12 50mm 105mm 130 65mm 36 60mm 94 05mm 41 50mm 2mm M3 M3...

Page 52: ...Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany Phone 49 941 8700 0 Fax 49 941 8700 180 www dallmeier com info dallmeier com...

Reviews: