18
Rev. 1.0.1 | © 2018 Dallmeier | www.dallmeier.com
MDF5400HD-DN Commissioning
8 Installation and Commissioning
The installation and commissioning of the device may only be carried out by qualified personnel.
To install the device, you will need different tools/accessories depending on the panel thickness of the suspended ceiling (see below).
Required tools/accessories for suspended ceilings with a panel thickness of 9 – 18 mm:
•
Drilling template with marking for the intended installation hole (Ø 70 mm)
•
Electrically powered jigsaw or hand saw (e.g. drywall utility saw) for circular cut-outs or drilling machine with hole saw (Ø 70 mm);
the used tool type must be suitable for the respective construction material such as plasterboard, wood, plastic, metal, etc.
•
Phillips
*)
-head screwdriver PH1 for fixing the dome housing in the ceiling panel by means of swiveling retaining wings
•
4 screws (Ø 3.5 mm; length depending on panel thickness) for fixing the encoder unit on the hidden side of the ceiling panel
Required tools/accessories for suspended ceilings with a panel thickness of less than 9 mm or more than 18 mm:
•
Drilling template with markings for the intended installation hole (Ø 70 mm) and the required drill holes (Ø 5 mm) when using anchors/dowels
•
Tool (e.g. center punch or awl) for marking drill hole locations through the drilling template
•
Electrically powered jigsaw or hand saw (e.g. drywall utility saw) for circular cut-outs or drilling machine with hole saw (Ø 70 mm);
the used tool type must be suitable for the particular construction material such as plasterboard, wood, plastic, metal, etc.
•
Three screws (Ø 3 – 4 mm) for fixing the dome housing and, depending on the construction material of the ceiling panel, suitable anchors/dowels
•
Drilling machine with drill bit (Ø 5 mm) when using anchors/dowels (type of drill bit suitable for the respective construction material)
•
4 screws (Ø 3.5 mm; length depending on panel thickness) for fixing the encoder unit on the hidden side of the ceiling panel
WARNING
Personal injury caused by collapsing of the suspended ceiling or by falling device
Risk of death or serious injury to the head
➡
Before installing the device, follow the manufacturer’s instructions regarding the maximum permissible carrying capacity of the
suspended ceiling or ceiling panel.
➡
Only use screws and, if necessary, anchors/dowels that are suitable for the construction material and thickness of the ceiling panel.