14.3.6.3 Alarm Action
ALARM ACTION SETUP
NO FCT FCTNO PRI DWL
01 -------- --- 1 ---
02 -------- --- 1 ---
03 -------- --- 1 ---
Save and Exit
NO
Alarm input number
FCT
Stored function type to be called by alarm:
P Preset
(Position Preset)
C Preset
(Camera Preset)
D/N
SCAN
TOUR
PATTERN
HOME
FCTNO
Stored function number (or type) to be called by alarm:
P Preset:
001
–
248
C Preset:
Default
,
Global
(
obsolet
),
Outdoor
,
Indoor
,
Dark Corner
,
Fast Movement
,
User
1
–
User
4
D/N:
Day
,
Night
Scan:
01
–
16
Tour:
01
–
08
Pattern:
01
–
08
PRI
Alarm priority (
1
–
3
): The lower number has higher priority.
DWL
Dwell time during multiple Position Presets:
2
,
5
,
10
,
20
,
30
,
40
,
50
,
60
,
120
seconds,
UNL
(imited)
3 levels of priority are available.
1 is the highest priority
Every priority level should be set only once.
The function of lower priority alarms won’t be serviced until the function of higher priority
alarms is completed.