Diagnostics & Troubleshooting
36
Code
Description
F
0
D
EPLD error
F
0
E
EPLD oscillator error
F
0
F
EPLD firmware is missing or corrupt
F
1
0
Firmware error
F
1
1
ProLink5 configuration error
F
1
2
PLR display error
F
1
3
VIN voltage error
F
x
x
Other self-test error
Note:
If a CAN sensor is not available for field use, the CAN error can be ignored; the
operator should fail the PLR only if the
ERR
LED is lit.
Troubleshooting via IDM
Daktronics Intelligent Device Management (IDM) is an internet-based diagnostic system
that analyzes the data collected from Daktronics equipment to identify malfunctions,
errors, and other issues. The IDM website is the primary source for accessing the
diagnostic data. For more information on using IDM, refer to the
Daktronics Intelligent
Device Management User Manual (DD2097912)
.
If a PLR-controlled display section shows either a blank module or incorrect data, follow
these steps:
1.
Open the IDM application.
2.
Click any visible diagnostic errors. The status window opens on the right side. Refer to
. If IDM does not show any visible errors, proceed to
Troubleshooting at the PLR615X Display (p.38)
Visible diagnostic errors
Status window
Help icon
Figure 36:
IDM Troubleshooting
Summary of Contents for PROLINK ROUTER 605 Series