Diagnostics & Troubleshooting
30
PLR605X Self-Test Mode
The PLR self-test mode is a diagnostic mode used to test internal systems and I/O ports.
During self-test mode, the PLR tests for correct operation and shows a pass/fail status on
the 7-segment display. If any failures are detected, error codes are displayed to define
the source of the failure.
To put the PLR605X into self-test
mode, refer to
follow these steps:
1.
Loop the SATA cable from
Port A to Port B on the
ProLink5 jacks.
2.
Loop the fiber cables from
Port A to Port B on the
ProLink6 jacks.
3.
Disconnect the power and
then reconnect the power.
When the self-test is complete,
disconnect power, remove loopback connections, and restart power. Refer to
and the following table for more information on the error
messages.
Self-Test Mode Messages
During self-test mode, the PLR605X displays the messages listed in the following table
on the 7-segment display. If any
E r r
message is displayed, the PLR should be sent in for
repair. Daktronics field personnel may also reference the
ProLink Router 605X (PLR605X)
Self-Test Manual (DD1750417)
for further information concerning the PLR self-test.
Code
Description
8
8
8
7-segment display test (held for two seconds)
t
s
t
Initial test in progress (held for 60 seconds)
P
A
S
All tests passed
E
r
r
Test failures reported
F
0
1
ProLink6 (fiber) Port A error
F
0
2
ProLink6 (fiber) Port B error
F
0
3
RJ45 In (Port A) error
F
0
4
RJ45 Out (Port B) error
F
0
5
ProLink5 (SATA) Port A error
F
0
6
ProLink5 (SATA) Port B error
F
0
7
ISAC error
F
0
8
Fan control error
F
0
9
Voltage error
7-Segment display
ProLink5 SATA
cable loopback
ProLink6 fiber
cable loopback
Power jack
Figure 29:
PLR605X Self-Test