Display and Control Overview
4
2 Display and Control Overview
This section describes generic power and signal paths for Daktronics digital billboards.
Refer to display-specific signal and riser drawings for component locations on your
display.
Display Control System Flow Overview
internal control system and the
remote power control device. The
control system bay or components
may vary slightly by display. Refer
to project-specific drawings for
display control location, signal
path, and power path.
Display Power
Overview
Each 400 W power supply powers
12 modules in BLD series billboards.
In most cases, the module power
path follows the signal path.
the power system in an individual
display section.
Power to the display section enters
into the power entrance and is
redistributed to the power supplies.
Refer to the layout drawing for
display-specific power distribution.
Display Signal
Overview
for display-specific signal routing.
Signal is sent from the DMP-8000 to the VIP-5160. The VIP-5160 sends signal to the PLR,
which sends the signal to the first module in the section. From that module, the signal is
sent to the other modules in the section. The PLR not only sends signal to the first module
in the chain but also receives signal from the last module in the chain and creates a
redundant signal path.
Section 200
Section 100
Display Front
Display Rear
3" Border
Painted All
Around
Lift Eye
Power
Entrance
Signal
Entrance
Internal Control
System
Ventilation
Intake
Ventilation
Exhaust
Doors
Spare
Parts
Support
Ledger
Figure 5:
BLD Series Component Locations
PS
PS
PS
PS
PS
PS
PS
30" MOD WHIP
30" MOD WHIP
30" MOD WHIP
30" MOD WHIP
30" MOD WHIP
30" MOD WHIP
30" MOD WHIP
30" MOD WHIP
60" MOD WHIP
60" MOD WHIP
60" MOD WHIP
60" MOD WHIP
60" MOD WHIP
60" MOD WHIP
Bay 1
Bay 2
Bay 3
Bay 4
C
R
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
Figure 6:
Power Example - Poster (11' x 22') Display