GB
153
4.8.1 Deleting the parameter settings of the receiver recognised by a control panel
The factory parameter settings of an output are restored using the control panel keypad.
With the control panel in installation mode, use the keypad to enter:
4.8 Deleting parameter-setting
output n° (from 1 to 8)
receiver n°
4.8.2 Overall deletionl
To return to factory parameter settings and delete all products recognised by the receiver:
1.
disconnect the receiver power supply,
2.
reconnect the power supply and press the test button at the same time, holding it down until a beep is issued (about 5 s),
3.
release the button and a long beep is issued to confirm the receiver’s return to factory parameter settings.
The receiver can be installed:
• inside,
• outside but in a location sheltered from the weather,
• making sure there is a distance of at least 2 metres between each product, except between two detectors,
• at a height above 1 m from the ground and clear of any obstacles (furniture, metallic structures, etc.),
• far away from possible sources of electrical disturbance (electricity meter, telephone cabinet, etc.).
The receiver cannot be installed:
• directly on a metallic surface,
• too close to electrical devices generating interference: electricity meter, telephone cabinet, computer, etc.
5. Installing the receiver
5.1 Choosing the best place to install the receiver
Before fixing the receiver in place, position it in the intended location and then test the radio range.
If the tests are satisfactory, fix the receiver in place. If not, move it to a different location.
5.2 Testing the radio range