When your alarm system is disarmed, the control panel will report the problem with the voice
message 

“beep, date, time, fire alarm, detector n° X”

.

... faults

Battery fault on the detector

If the sound indication of the battery fault occurs at an inappropriate time, it is possible to
postpone its occurrence for an 8-hour delay over a maximum 7-day period by pressing the
test button until you hear the 1st beep. This is the time period available for replacing the
Lithium battery.

Battery fault on the control panel

Following a system command, the control panel issues the following voice message: 

“beep,

fault, battery, detector n° X”

.

7. Indications...

iMPoRtAnt: in order not to wake you up, audible alarms resulting from power problems 

or technical problems are shut down during the night. Any faults are indicated either 

after daybreak for a period of more than 10 minutes or 12 hours after their occurrence.

iMPoRtAnt: when a

battery fault occurs, the

detector continues to

function perfectly for

30 days. nevertheless, 

it is advisable to replace 

the battery as soon as

possible.

Heat detector transmitting

the fault signal
other hard-wired

interconnected heat

detectors

the LED flashes 

every 5 sec.

-

2 fast beeps 

every 60 sec.

-

-

-

Red LeD indicating

detector status

White LeD

Sounding

Summary of Contents for 155-21X

Page 1: ...Upgraded for e Nova applications...

Page 2: ...an abnormal speed or when the room temperature reaches between 54 C and 70 C also refer to the table in the Technical Data section The heat detector is especially suitable for detecting res that spre...

Page 3: ...r provided with this product Heat detector transmitting the heat detection signal other hard wired interconnected heat detectors the LED ashes quickly a built in modulated alarm sounds on a continuous...

Page 4: ...und The red LED ashes for 15 sec then once every 10 sec to indicate that the detector is working normally 2 Power supply 3 Recognition programming iMPoRtAnt during recognition programming the product...

Page 5: ...shim made of non magnetic material wood or plastic the detector must not be placed in rooms where a sudden and considerable rise in the room temperature would cause untimely triggering of the alarms...

Page 6: ...t if there is no voice message move the heat detector closer to the control panel le 2 Put the control panel back in user mode by pressing in rooms where the relative humidity might rise above 95 with...

Page 7: ...opriate plugs and screws Fixing with ush mounting box 1 For 60 mm diameter boxes use holes marked 2 For 85 mm diameter boxes use holes marked 3 Fix the base using suitable screws 60 85 60 85 optional...

Page 8: ...e g a 155 21X can be connected with 155 21X heat detectors or 151 21X smoke detectors For 15 mm2 wires the overall network length must not exceed 400 m 3 Clip the connector block back in place 4 Lock...

Page 9: ...perature measurement If the heat sensor is faulty the heat detector indicates that there is a technical fault see Indications section There is therefore no need to test the detector using a source of...

Page 10: ...lephone dialler Stop the sirens and check that the control panel has memorised the alarm see Indications section iMPoRtAnt these tests should be carried out at least once a month and notably when you...

Page 11: ...etector stops its built in sounding The LED indicating the status of the detector ashes every 2 sec Following the 15 min disable period the detector is automatically reset to normal operation with the...

Page 12: ...stem command the control panel issues the following voice message beep fault battery detector n X 7 Indications iMPoRtAnt in order not to wake you up audible alarms resulting from power problems or te...

Page 13: ...r head You should vacuum clean the detection head slots if there is a lot of dust in the room 8 Maintenance Heat detector transmitting the fault signal other hard wired interconnected heat detectors t...

Page 14: ...ent reliability Dispose of the waste lithium power pack in an appropriate recycling bin 8 2 Changing the battery if the optional opening of the detector is not locked see Fixing 1 Remove the detector...

Page 15: ...ctor status alerts triggered faults White LED safety lighting in case of detection Built in sounding 85 dB at 3 m in case of detection 75 dB at 3 m during testing or fault indication Hard wired interc...

Page 16: ...6 00 3 7 13 16 00 5 4 09 10 00 10 2 00 5 30 20 1 00 3 13 30 0 40 2 25 or depending on the temperature rise speed A2 class detector response time according to EN 54 5 chapter 5 4 3 Examples if the temp...

Page 17: ...the user Do not forget to remove the plastic cover when the work is finished Heat detection 1 All heat detectors the LED ashes once every 10 sec Red LeD indicating detector status White LeD Sounding H...

Page 18: ...l the rst beep sounds You should contact your installation engineer within this same period in order to rectify the problem Following the 15 min disable period the detector is automatically reset to n...

Page 19: ...95 eC in compliance with the following harmonised European standards This product can be used in all EU EEA Countries and Switzerland Crolles 02 01 2013 Signature Patrick Bernard Director of Research...

Page 20: ...2280612004 01 2013...

Reviews: