1-1  TECHNICAL SPECIFICATIONS

FXDQ20PBVE

FXDQ25PBVE

FXDQ32PBVE

Capacity

Cooling

kW

2.2

2.8

3.6

Heating

kW

2.5

3.2

4.0

Power Input 
(50Hz)

Cooling

kW

0.086

0.086

0.089

Heating

kW

0.067

0.067

0.070

Power Input 
(60Hz)

Cooling

kW

0.092

0.092

0.095

Heating

kW

0.073

0.073

0.076

Casing

Material

Galvanised steel plate

Dimensions

Unit

Height

mm

200

200

200

Width

mm

700

700

700

Depth

mm

620

620

620

Weight

Unit

kg

23

23

23

Heat 
Exchanger

Dimensions

Nr of Rows

2

2

3

Fin Pitch

mm

1.5

1.5

1.5

Face 
Area

0.126

0.126

0.126

Nr of Stages

12

12

12

Fan

Type

Sirocco fan

Air Flow Rate

Cooling

High high m³/min

8.0

8.0

8.0

High

m³/min

7.2

7.2

7.2

Low

m³/min

6.4

6.4

6.4

Fan

External static 
pressure

High

Pa

30

30

30

Standard Pa

10

10

10

Motor

Output 
(high)

W

62

62

62

Drive

Direct drive

Cooling

Sound 
Pressure

High high dBA

33

33

33

High

dBA

31

31

31

Low

dBA

29

29

29

Piping 
connections

Liquid (OD)

Type

Flare connection

Diameter mm

6.35

6.35

6.35

Gas

Type

Flare connection

Diameter mm

12.7

12.7

12.7

Drain

Diameter mm

VP20 (I.D. 20/O.D. 26)

Sound absorbing insulation

Foamed polyethylene

Air Filter

Removable/washable/Mildew proof

Refrigerant control

Electronic expansion valve

Temperature control

Microprocessor thermostat for cooling and heating

Safety devices

Fuse

Fan motor thermal protector

Standard 
Accessories

Standard Accessories

Operation manual

Installation manual

Drain hose

Sealing pads

Clamps
Washer

Insulation for fitting

Clamp metal

Washer fixing plate

Screws for duct flanges

Air filter

Product Quality Certificate

Summary of Contents for VRV-WII Series

Page 1: ...technical data Slim Concealed Ceiling Unit FXDQ PBVE air conditioning systems...

Page 2: ......

Page 3: ...air conditioning systems technical data Slim Concealed Ceiling Unit FXDQ PBVE...

Page 4: ......

Page 5: ...ications 50Hz 3 Electrical Specifications 60Hz 3 2 Safety device settings 4 3 Options 5 4 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 7 5 Dimensional drawing centre of gravity...

Page 6: ...te Cooling High high m min 8 0 8 0 8 0 High m min 7 2 7 2 7 2 Low m min 6 4 6 4 6 4 Fan External static pressure High Pa 30 30 30 Standard Pa 10 10 10 Motor Output high W 62 62 62 Drive Direct drive C...

Page 7: ...0 8 0 8 0 8 Maximum fuse amps MFA A 15 15 15 Full load amps FLA A 0 6 0 6 0 6 Voltage range Minimum V 10 Maximum V 10 Notes Voltage range units are suitable for use on electrical systems where voltag...

Page 8: ...emote control BRC2C51 Remote control for hotel use BRC3A61 Kit name FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE Central remote control DCS302CA51 Unified on off control DCS301BA5...

Page 9: ...3 6 2 2 16 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 5 2 2 18 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 5 2 2 20 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 4 2 2 21 0 1 9...

Page 10: ...9 16 7 17 0 2 1 2 1 2 0 2 0 2 0 2 0 14 7 15 0 2 2 2 2 2 2 2 2 2 2 2 1 12 6 13 0 2 3 2 3 2 3 2 3 2 3 2 3 10 5 11 0 2 4 2 4 2 4 2 4 2 4 2 4 9 5 10 0 2 5 2 4 2 4 2 4 2 4 2 4 8 5 9 1 2 5 2 5 2 5 2 5 2 5 2...

Page 11: ...500 All around 16 4 7 hole All around Suspension bolt pitch Suspension bolt 4 M8 M10 14 M4 Holes All around 16 M4 Holes 700 Service space of installation box for adaptor PCB NOTES 1 In case of back s...

Page 12: ...Indoor Units SLIM CONCEALED CEILING UNIT FXDQ PBVE 1 5 VRV Systems Indoor Units 8 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FXDQ20 25 32PB 4D049300D...

Page 13: ...ems Indoor Units 9 Indoor Units SLIM CONCEALED CEILING UNIT FXDQ PBVE 6 Piping diagram FXDQ20 25 32PB FXDQ40 50 63NB 4D060927 Gas side Liquid side Electronic expansion valve Filter Filter Indoor heat...

Page 14: ...1C Z2C Noise filter ferrite core C1 Capacitor M1F R2T Thermistor coil 1 Wired remote control F1U Fuse F5A 250V R3T Thermistor coil 2 R1T Thermistor air HAP Light emitting diode service monitor green S...

Page 15: ...WD Heating Return air temperature 20 C DB 15 C WB Outdoor temperature 7 C DB 6 C WB 3 Measuring place Anechoic chamber 4 Location of microphone 5 The operation condition is external static pressure 1...

Page 16: ...e h i g h E S P Lower limit of external static pressure high ESP Low standard ESP Low high ESP High high ESP Air flow rate m3 min External static pressure NOTES 1 The remote control can be used to swi...

Page 17: ......

Page 18: ...ed therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related...

Reviews: