Sound data

8 - 1 Sound pressure spectrum

4D060945

NOTE

1

Over All (dB):
(B, G, N is already rectified)

2

Operating conditons:

Power source: 220~240V  50Hz / 220V 60Hz

Cooling:  Return air temperature: 27°C DB, 19°C WB

Outdoor temperature: 35°C DB, 24 °C WD

Heating:  Return air temperature: 20°C DB, 15°C WB

Outdoor temperature: 7°C DB, 6°C WB

3

Measuring place: Anechoic chamber

4

Location of microphone

5

The operation condition is external static pressure 10 Pa. Operation noise differ with 
operation and ambient conditions.

O

ct

ave

 band sound pr

es

sur

e level 

   dB(

0dB=0.0002μbar)

Octave band center frequency (Hz)

Approximate 

threshold hearing 

for continuous 

noise

FXDQ20PB

Scale

Air flow rate

HH

H

L

A

33.0

31.0

29.0

C

39.0

37.5

36.0

Discharge

Suction

Duct

Duct

1m

2m

1,5m

Microphone

4D060946

NOTE

1

Over All (dB):
(B, G, N is already rectified)

2

Operating conditons:

Power source: 220~240V  50Hz / 220V 60Hz

Cooling:  Return air temperature: 27°C DB, 19°C WB

Outdoor temperature: 35°C DB, 24 °C WD

Heating:  Return air temperature: 20°C DB, 15°C WB

Outdoor temperature: 7°C DB, 6°C WB

3

Measuring place: Anechoic chamber

4

Location of microphone

5

The operation condition is external static pressure 10 Pa. Operation noise differ with 
operation and ambient conditions.

O

ct

ave

 band sound pr

es

sur

e level 

   dB(

0dB=0.0002μbar)

Octave band center frequency (Hz)

Approximate 

threshold hearing 

for continuous 

noise

FXDQ25PB

Scale

Air flow rate

HH

H

L

A

33.0

31.0

29.0

C

39.0

37.5

36.0

Discharge

Suction

Duct

Duct

1m

2m

1,5m

Microphone

4D060947

NOTE

1

Over All (dB):
(B, G, N is already rectified)

2

Operating conditons:

Power source: 220~240V  50Hz / 220V 60Hz

Cooling:  Return air temperature: 27°C DB, 19°C WB

Outdoor temperature: 35°C DB, 24 °C WD

Heating:  Return air temperature: 20°C DB, 15°C WB

Outdoor temperature: 7°C DB, 6°C WB

3

Measuring place: Anechoic chamber

4

Location of microphone

5

The operation condition is external static pressure 15 Pa. Operation noise differ with 
operation and ambient conditions.

O

ct

ave

 band sound pr

es

sur

e level 

   dB(

0dB=0.0002μbar)

Octave band center frequency (Hz)

Approximate 

threshold hearing 

for continuous 

noise

FXDQ32PB

Scale

Air flow rate

HH

H

L

A

33.0

31.0

29.0

C

39.0

37.5

36.0

Discharge

Suction

Duct

Duct

1m

2m

1,5m

Microphone

Summary of Contents for VRV-WII Series

Page 1: ...technical data Slim Concealed Ceiling Unit FXDQ PBVE air conditioning systems...

Page 2: ......

Page 3: ...air conditioning systems technical data Slim Concealed Ceiling Unit FXDQ PBVE...

Page 4: ......

Page 5: ...ications 50Hz 3 Electrical Specifications 60Hz 3 2 Safety device settings 4 3 Options 5 4 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 7 5 Dimensional drawing centre of gravity...

Page 6: ...te Cooling High high m min 8 0 8 0 8 0 High m min 7 2 7 2 7 2 Low m min 6 4 6 4 6 4 Fan External static pressure High Pa 30 30 30 Standard Pa 10 10 10 Motor Output high W 62 62 62 Drive Direct drive C...

Page 7: ...0 8 0 8 0 8 Maximum fuse amps MFA A 15 15 15 Full load amps FLA A 0 6 0 6 0 6 Voltage range Minimum V 10 Maximum V 10 Notes Voltage range units are suitable for use on electrical systems where voltag...

Page 8: ...emote control BRC2C51 Remote control for hotel use BRC3A61 Kit name FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE Central remote control DCS302CA51 Unified on off control DCS301BA5...

Page 9: ...3 6 2 2 16 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 5 2 2 18 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 5 2 2 20 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 4 2 2 21 0 1 9...

Page 10: ...9 16 7 17 0 2 1 2 1 2 0 2 0 2 0 2 0 14 7 15 0 2 2 2 2 2 2 2 2 2 2 2 1 12 6 13 0 2 3 2 3 2 3 2 3 2 3 2 3 10 5 11 0 2 4 2 4 2 4 2 4 2 4 2 4 9 5 10 0 2 5 2 4 2 4 2 4 2 4 2 4 8 5 9 1 2 5 2 5 2 5 2 5 2 5 2...

Page 11: ...500 All around 16 4 7 hole All around Suspension bolt pitch Suspension bolt 4 M8 M10 14 M4 Holes All around 16 M4 Holes 700 Service space of installation box for adaptor PCB NOTES 1 In case of back s...

Page 12: ...Indoor Units SLIM CONCEALED CEILING UNIT FXDQ PBVE 1 5 VRV Systems Indoor Units 8 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FXDQ20 25 32PB 4D049300D...

Page 13: ...ems Indoor Units 9 Indoor Units SLIM CONCEALED CEILING UNIT FXDQ PBVE 6 Piping diagram FXDQ20 25 32PB FXDQ40 50 63NB 4D060927 Gas side Liquid side Electronic expansion valve Filter Filter Indoor heat...

Page 14: ...1C Z2C Noise filter ferrite core C1 Capacitor M1F R2T Thermistor coil 1 Wired remote control F1U Fuse F5A 250V R3T Thermistor coil 2 R1T Thermistor air HAP Light emitting diode service monitor green S...

Page 15: ...WD Heating Return air temperature 20 C DB 15 C WB Outdoor temperature 7 C DB 6 C WB 3 Measuring place Anechoic chamber 4 Location of microphone 5 The operation condition is external static pressure 1...

Page 16: ...e h i g h E S P Lower limit of external static pressure high ESP Low standard ESP Low high ESP High high ESP Air flow rate m3 min External static pressure NOTES 1 The remote control can be used to swi...

Page 17: ......

Page 18: ...ed therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related...

Reviews: