background image

ÉEEDEN09-204eËÍ

Daikin Europe N.V. is approved by LRQA for its
Quality Management System in accordance with
the ISO9001 standard. ISO9001 pertains to
quality assurance regarding design,
development, manufacturing as well as to
services related to the product. 

Daikin units comply with the European
regulations that guarantee the safety of the
product.

E

E

D

EN

09

-2

04

 •

 0

7/

2

00

8 •

 Co

py

ri

gh

t ©

 Da

ik

in

Th

e pr

ese

n

p

u

b

lic

at

ion

 su

per

sed

es EE

DE

N08-204

Pri

n

te

d in

 Be

lg

iu

m by La

nno

o  

(w

w

w

.la

nno

op

ri

nt

.b

e

), 

a

 c

o

mp

any

 w

h

o

se

 co

nc

er

n fo

r

the envir

o

nmont is 

set

 in the 

E

M

A

S a

n

d

 ISO 14001 syste

ms.

 

Re

spo

n

sib

le E

d

ito

r:

 Da

ik

in 

E

u

ro

pe N.

V.

, Za

ndvo

or

des

tra

a

300,

 B- 8400 Oos

tende

The present publication is drawn up by way of information
only and does not constitute an offer binding upon Daikin
Europe N.V.. Daikin Europe N.V. has compiled the content of
this publication to the best of its knowledge. No express or
implied warranty is given for the completeness, accuracy,
reliability or fitness for particular purpose of its content and the
products and services presented therein. Specifications are
subject to change without prior notice. Daikin Europe N.V.
explicitly rejects any liability for any direct or indirect damage,
in the broadest sense, arising from or related to the use and/or
interpretation of this publication. All content is copyrighted by
Daikin Europe N.V..

VRV

®

 products are not within the scope of the

Eurovent certification programme.

Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende

Daikin’s unique position as a manufacturer
of air conditioning equipment, compressors
and refrigerants has led to its close
involvement in environmental issues. For
several years Daikin has had the intension to
become a leader in the provision of products
that have limited impact on the
environment. This challenge demands the
eco design and development of a wide
range of products and an energy
management system, resulting in energy
conservation and a reduction of waste.

ISO14001 assures an effective environmental
management system in order to help protect
human health and the environment from the
potential impact of our activities, products and
services and to assist in maintaining and
improving the quality of the environment.

Summary of Contents for VRV-WII Series

Page 1: ...technical data Slim Concealed Ceiling Unit FXDQ PBVE air conditioning systems...

Page 2: ......

Page 3: ...air conditioning systems technical data Slim Concealed Ceiling Unit FXDQ PBVE...

Page 4: ......

Page 5: ...ications 50Hz 3 Electrical Specifications 60Hz 3 2 Safety device settings 4 3 Options 5 4 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 7 5 Dimensional drawing centre of gravity...

Page 6: ...te Cooling High high m min 8 0 8 0 8 0 High m min 7 2 7 2 7 2 Low m min 6 4 6 4 6 4 Fan External static pressure High Pa 30 30 30 Standard Pa 10 10 10 Motor Output high W 62 62 62 Drive Direct drive C...

Page 7: ...0 8 0 8 0 8 Maximum fuse amps MFA A 15 15 15 Full load amps FLA A 0 6 0 6 0 6 Voltage range Minimum V 10 Maximum V 10 Notes Voltage range units are suitable for use on electrical systems where voltag...

Page 8: ...emote control BRC2C51 Remote control for hotel use BRC3A61 Kit name FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE Central remote control DCS302CA51 Unified on off control DCS301BA5...

Page 9: ...3 6 2 2 16 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 5 2 2 18 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 5 2 2 20 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 4 2 2 21 0 1 9...

Page 10: ...9 16 7 17 0 2 1 2 1 2 0 2 0 2 0 2 0 14 7 15 0 2 2 2 2 2 2 2 2 2 2 2 1 12 6 13 0 2 3 2 3 2 3 2 3 2 3 2 3 10 5 11 0 2 4 2 4 2 4 2 4 2 4 2 4 9 5 10 0 2 5 2 4 2 4 2 4 2 4 2 4 8 5 9 1 2 5 2 5 2 5 2 5 2 5 2...

Page 11: ...500 All around 16 4 7 hole All around Suspension bolt pitch Suspension bolt 4 M8 M10 14 M4 Holes All around 16 M4 Holes 700 Service space of installation box for adaptor PCB NOTES 1 In case of back s...

Page 12: ...Indoor Units SLIM CONCEALED CEILING UNIT FXDQ PBVE 1 5 VRV Systems Indoor Units 8 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FXDQ20 25 32PB 4D049300D...

Page 13: ...ems Indoor Units 9 Indoor Units SLIM CONCEALED CEILING UNIT FXDQ PBVE 6 Piping diagram FXDQ20 25 32PB FXDQ40 50 63NB 4D060927 Gas side Liquid side Electronic expansion valve Filter Filter Indoor heat...

Page 14: ...1C Z2C Noise filter ferrite core C1 Capacitor M1F R2T Thermistor coil 1 Wired remote control F1U Fuse F5A 250V R3T Thermistor coil 2 R1T Thermistor air HAP Light emitting diode service monitor green S...

Page 15: ...WD Heating Return air temperature 20 C DB 15 C WB Outdoor temperature 7 C DB 6 C WB 3 Measuring place Anechoic chamber 4 Location of microphone 5 The operation condition is external static pressure 1...

Page 16: ...e h i g h E S P Lower limit of external static pressure high ESP Low standard ESP Low high ESP High high ESP Air flow rate m3 min External static pressure NOTES 1 The remote control can be used to swi...

Page 17: ......

Page 18: ...ed therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related...

Reviews: