• Indoor Units • SLIM CONCEALED CEILING UNIT • FXDQ-PBVE

1

2

• VRV

®

 Systems • Indoor Units

4

2

Safety device settings

3

Options

FXDQ20,25,32PB

FXDQ40,50,63NB

4D060926

Kit name

FXDQ20PB

FXDQ25PB

FXDQ32PB

PC boad (A1P) fuse

250V 5A

Fan motor thermal protector

OFF: 250V 5A 

 

5°C OFF

ON: 83 

 

15°C ON

FXDQ40NB

FXDQ50NB

FXDQ63NB

FXDQ20,25,32PB

FXDQ40,50,63NB

Individual control systems

Centralized control system

Other options

4D060939

Kit name

FXDQ20PBVE

FXDQ25PBVE

FXDQ32PBVE

FXDQ40NBVE

FXDQ50NBVE

FXDQ63NBVE

Wired remote control

BRC1D52

Infrared remote 
control

H/P

BRC4C65

C/O

BRC4C66

Simplified remote control

BRC2C51

Remote control for hotel use

BRC3A61

Kit name

FXDQ20PBVE

FXDQ25PBVE

FXDQ32PBVE

FXDQ40NBVE

FXDQ50NBVE

FXDQ63NBVE

Central remote control

DCS302CA51

Unified on/off control

DCS301BA51

Schedule timer

DST301BA51

Kit name

FXDQ20PBVE

FXDQ25PBVE

FXDQ32PBVE

FXDQ40NBVE

FXDQ50NBVE

FXDQ63NBVE

Adapter for wiring 

KRP1B56

Wiring adapter for electrical 
appendices (1)

KRP2A53

Wiring adapter for electrical 
appendices (2)

KRP4A54

Remote sensor

KRCS01-1B

Installation box for adapter 
PCB.

KBP1BA101

Electrical box 
with earth 
terminal

2 blocks

KJB212AA

3 blocks

KJB311AA

Noise filter (for 
electromagnetic interface 
use only)

DST301BA51

External control adapter for 
outdoor unit (must be 
installed on indoor units)

DTA104A53

Insulation kit for high 
humidity

KDT25N32

KDT25N50

KDT25N63

Summary of Contents for VRV-WII Series

Page 1: ...technical data Slim Concealed Ceiling Unit FXDQ PBVE air conditioning systems...

Page 2: ......

Page 3: ...air conditioning systems technical data Slim Concealed Ceiling Unit FXDQ PBVE...

Page 4: ......

Page 5: ...ications 50Hz 3 Electrical Specifications 60Hz 3 2 Safety device settings 4 3 Options 5 4 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 7 5 Dimensional drawing centre of gravity...

Page 6: ...te Cooling High high m min 8 0 8 0 8 0 High m min 7 2 7 2 7 2 Low m min 6 4 6 4 6 4 Fan External static pressure High Pa 30 30 30 Standard Pa 10 10 10 Motor Output high W 62 62 62 Drive Direct drive C...

Page 7: ...0 8 0 8 0 8 Maximum fuse amps MFA A 15 15 15 Full load amps FLA A 0 6 0 6 0 6 Voltage range Minimum V 10 Maximum V 10 Notes Voltage range units are suitable for use on electrical systems where voltag...

Page 8: ...emote control BRC2C51 Remote control for hotel use BRC3A61 Kit name FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE Central remote control DCS302CA51 Unified on off control DCS301BA5...

Page 9: ...3 6 2 2 16 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 5 2 2 18 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 5 2 2 20 0 1 9 1 6 2 3 1 9 2 6 2 1 2 8 2 1 3 0 2 2 3 4 2 2 3 4 2 2 21 0 1 9...

Page 10: ...9 16 7 17 0 2 1 2 1 2 0 2 0 2 0 2 0 14 7 15 0 2 2 2 2 2 2 2 2 2 2 2 1 12 6 13 0 2 3 2 3 2 3 2 3 2 3 2 3 10 5 11 0 2 4 2 4 2 4 2 4 2 4 2 4 9 5 10 0 2 5 2 4 2 4 2 4 2 4 2 4 8 5 9 1 2 5 2 5 2 5 2 5 2 5 2...

Page 11: ...500 All around 16 4 7 hole All around Suspension bolt pitch Suspension bolt 4 M8 M10 14 M4 Holes All around 16 M4 Holes 700 Service space of installation box for adaptor PCB NOTES 1 In case of back s...

Page 12: ...Indoor Units SLIM CONCEALED CEILING UNIT FXDQ PBVE 1 5 VRV Systems Indoor Units 8 5 Dimensional drawing centre of gravity 5 2 Centre of gravity FXDQ20 25 32PB 4D049300D...

Page 13: ...ems Indoor Units 9 Indoor Units SLIM CONCEALED CEILING UNIT FXDQ PBVE 6 Piping diagram FXDQ20 25 32PB FXDQ40 50 63NB 4D060927 Gas side Liquid side Electronic expansion valve Filter Filter Indoor heat...

Page 14: ...1C Z2C Noise filter ferrite core C1 Capacitor M1F R2T Thermistor coil 1 Wired remote control F1U Fuse F5A 250V R3T Thermistor coil 2 R1T Thermistor air HAP Light emitting diode service monitor green S...

Page 15: ...WD Heating Return air temperature 20 C DB 15 C WB Outdoor temperature 7 C DB 6 C WB 3 Measuring place Anechoic chamber 4 Location of microphone 5 The operation condition is external static pressure 1...

Page 16: ...e h i g h E S P Lower limit of external static pressure high ESP Low standard ESP Low high ESP High high ESP Air flow rate m3 min External static pressure NOTES 1 The remote control can be used to swi...

Page 17: ......

Page 18: ...ed therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related...

Reviews: