Specifications
SiUS34-907
14
Specifications
Ceiling Mounted Duct Type
Notes:
1 Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB (27°CDB), 67°FWB (19.4°CWB)
Standard external static pressure
Outdoor temperature: 95°FDB (35°CDB)
Equivalent ref. piping length: 25ft (7.5 m), (Horizontal)
2 Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB (21°CDB).
Standard external static pressure
Outdoor temperature: 47°FDB (8.3°CDB), 43°FWB (6°FWB)
Equivalent ref. piping length: 25ft (7.5 m), (Horizontal)
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4 External static pressure is changeable in 7 (FXMQ07, 09, 12PVJU), 14 (FXMQ18, 24, 30, 36, 48PVJU) stages within the ( )
range by remote controller.
5 Air filter is not standard accessory, but please mount it in the duct system of the suction side.
Select its colorimetric method (gravity method) 50% or more.
Model
FXMQ36PVJU
FXMQ48PVJU
1,
3 Cooling Capacity
Btu/h
36,000
48,000
2,
3 Heating Capacity
Btu/h
40,000
54,000
Casing / Color
Galvanized Steel Plate
Galvanized Steel Plate
Dimensions: (H×W×D)
in. (mm)
11-13/16
×
55-1/8
×
27-9/16 (300 x 1400 x 700)
11-13/16
×
55-1/8
×
27-9/16 (300 x 1400 x 700)
Coil (Cross
Fin Coil)
Rows×Stages×FPI
3×16×15
3×16×15
Face Area
ft² (m²)
4.12 (1.3)
4.12 (1.3)
Fan
Model
—
—
Type
Sirocco Fan
Sirocco Fan
Motor Output
kw
0.04
0.04
Airflow Rate (HH/H/L)
cfm
1130/953/812
1377/1165/988
External Static Pressure
4
”Wg
0.80-0.20
0.80-0.20
Drive
Direct Drive
Direct Drive
Temperature Control
Microprocessor Thermostat for Cooling and Heating
Microprocessor Thermostat for Cooling and Heating
Sound Absorbing Thermal Insulation Material
Glass Fiber
Glass Fiber
Air Filter
5
5
Piping
Connections
Liquid Pipes
in. (mm)
φ
3/8 (9.5) (Flare Connection)
φ
3/8 (9.5) (Flare Connection)
Gas Pipes
in. (mm)
φ
5/8 (15.8) (Flare Connection)
φ
5/8 (15.8) (Flare Connection)
Drain Pipe
in. (mm)
VP25
External Dia. 1-1/4 (31.8)
Internal Dia. 1 (25.4)
VP25
External Dia. 1-1/4 (31.8)
Internal Dia. 1 (25.4)
Machine Weight (Mass)
Lbs (kg)
102 (46)
102 (46)
Sound Level (H/L)
dBA
45/41
45/41
Safety Devices
Fuse,
Fan Driver Overload Protector
Fuse,
Fan Driver Overload Protector
Refrigerant Control
Electronic Expansion Valve
Electronic Expansion Valve
Connectable outdoor unit
R-410A Series
R-410A Series
Standard Accessories
Operation Manual, Installation Manual, Drain Hose, Sealing
Pads, Clamp Metal, Air Discharge Flange, Air Suction Flange
Operation Manual, Installation Manual, Drain Hose,
Sealing Pads, Clamp Metal, Air Discharge Flange, Air
Suction Flange
Drawing No.
3D066117B
(
)
(
)
Summary of Contents for VRV III-S RXYMQ36 48PVJU
Page 1: ...RXYMQ36 48PVJU R 410A Heat Pump 60Hz SiUS34 907...
Page 9: ...SiUS34 907 Safety Considerations viii...
Page 237: ...Wiring Diagrams SiUS34 907 228 Appendix 2 2 Field Wiring RXYMQ36 48PVJU 3D065370...
Page 238: ...SiUS34 907 Wiring Diagrams Appendix 229 2 3 Indoor Unit FXFQ12M 18M 24M 30M 36MVJU 3D042620C...
Page 239: ...Wiring Diagrams SiUS34 907 230 Appendix FXZQ07M 09M 12M 18MVJU 3D059263...
Page 240: ...SiUS34 907 Wiring Diagrams Appendix 231 FXDQ07M 09M 12M 18M 24MVJU 3D050501A...
Page 241: ...Wiring Diagrams SiUS34 907 232 Appendix FXMQ07P 09P 12P 18P 24P 30P 36P 48PVJU 3D065984A...
Page 242: ...SiUS34 907 Wiring Diagrams Appendix 233 FXHQ12M 24M 36MVJU 3D048116A...
Page 243: ...Wiring Diagrams SiUS34 907 234 Appendix FXAQ07M 09M 12M 18M 24MVJU 3D046039D...
Page 244: ...SiUS34 907 Wiring Diagrams Appendix 235 FXLQ12M 18M 24MVJU FXNQ12M 18M 24MVJU 3D045644A...
Page 247: ...Option List SiUS34 907 238 Appendix...
Page 249: ...Example of Connection 240...
Page 263: ...Precautions for New Refrigerant R 410A SiUS34 907 254 Precautions for New Refrigerant R 410A...