![background image](http://html1.mh-extra.com/html/daikin/super-multi-nx-ctxs07jvju/super-multi-nx-ctxs07jvju_service-manual_3423788244.webp)
SiUS12-928_B
Outdoor Unit: 3MXS24JVJU, 4MXS32GVJU
Removal Procedure
236
7
Disconnect the connector
for the gas pipe
thermistors [S92] and pull
out the clamp.
When reassembling, insert
the clamp into the hole.
8
Disconnect the connector
for the thermistors [S90]
and pull out the clamp.
When reassembling, insert
the clamp into the hole.
9
The wire harness of the
thermistors is hooked
under the electrical box.
Unhook it and pull out the
clamp.
Step
Procedure
Points
[S92]
(R10537)
Clamp
[S92]
(R17356)
[S90]
(R10538)
Clamp
Thermistor ASSY
(R17142)
Clamp
Hook
(R6420)
Fixing position for the
thermistor harness
When reassembling, insert
the clamp into the small hole.