Removal Procedure
2
Disconnect the connector
for the four-way valve coil
[S80].
When reassembling, insert
the clamp into the hole as
below.
3
Disconnect the
connectors for the
thermistors [S90] [S92]
[S93] and the overload
protector [S40].
[S40]: overload protector
[S90]: thermistors
(outdoor temperature, outdoor
heat exchanger, discharge
pipe)
[S92]: gas pipe thermistors
[S93]: liquid pipe thermistors
Pull out the clamp.
When reassembling, insert
each clamp of the themistors
into one of the holes as below.
When reassembling, insert
each clamp into the holes.
When reassembling, the
thermistor harness should be
placed between the electrical
box and the reactor harness
as below.
Step
Procedure
Points
(R17398)
[S80]
Clamp
(R17397)
[S40]
[S90] [S92] [S93]
(R17399)
[S92]
[S93]
(R17401)
Reactor
harness
Thermistor
ASSY
(R17093)
Reactor harness
Thermistor
ASSY