![background image](http://html1.mh-extra.com/html/daikin/super-multi-nx-ctxs07jvju/super-multi-nx-ctxs07jvju_service-manual_3423788228.webp)
SiUS12-928_B
Outdoor Unit: 2MXS18GVJU
Removal Procedure
220
1.9
Removal of Compressor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the terminal
cover.
2
Disconnect the
compressor lead wires.
3
Remove the 2 sheets of
putty.
4
Remove the 3 nuts.
Terminal cover
(R2205)
(R17408)
V (yellow)
W (blue)
N (brown)
U (red)
Putty
(R10373)