![background image](http://html1.mh-extra.com/html/daikin/super-multi-nx-ctxs07jvju/super-multi-nx-ctxs07jvju_service-manual_3423788220.webp)
SiUS12-928_B
Outdoor Unit: 2MXS18GVJU
Removal Procedure
212
1.4
Removal of Fan Motor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the nut and
remove the outdoor fan.
Preparation
Disconnect the connector for the
fan motor and release the fan
motor lead wire according to the
“Removal of Electrical Box”.
When reassembling, align the
mark of outdoor fan with
the D-cut section of motor
shaft.
Nut size : M6
2
Remove the 2 screws of
the fan motor fixing flame.
When reassembling, fix the
fan motor lead wire to avoid
contact with the outdoor fan.
3
Open the 2 hooks and
release the fan motor lead
wire.
4
Remove the 4 screws and
remove the fan motor.
Nut
Outdoor fan
(R17349)
10 mm
(0.39 inch)
(R17404)
(R17350)
Fan motor
fixing
frame
(Backside)
(R5567)
(R5568)