background image

FDBQ25B8V1
Split series room air conditioners
Multi system room air conditioners
4PW23698-1

Installation manual

4

FIELD SUPPLY

K1R........................ Magnetic relay

EH.......................... Electrical heater

Field cable and field fuse

Do not connect wires of different gauge to the same power
supply terminal. (Looseness in the connection may cause
overheating.)

When connecting wires of the same gauge, connect them
according to the figure.

I

NSTALLING

 

THE

 

REMOTE

 

CONTROLLER

Installation instructions and field settings

Refer to the installation manual delivered with the optional remote
controller.

Setting the air filter replacement

Setting

The remote controller displays 

when it is time to clean the

air filters.

Change the second code n° according to the table depending on
the amount of dirt or dust in the room (the 2nd code n° is factory
set to '01' for light air filter contamination).

Setting the remote sensor

The customer has the ability to select the thermistor. Both unit and
remote controller are equipped with a thermistor.

Setting

Change the second code n° according to the table to enable or
disable the remote sensor

Wired remote 
controller

:

Details of wired 
remote controller

:

Adaptor for wiring

:

Terminals for 
operation indicator

:

Fan operation

:

Compressor operation

:

Switch box

:

NOTE

1.

When using the central remote controller, see manual
for connection to the unit.

2.

The remote controller model varies according to the
combination system. See technical materials and
catalogs, etc. before connecting.

NOTE

In case of installing an electric heater, execute the
additional wiring and use a separate power supply of
1~50 Hz 230 V.

Use solid core cables to avoid loosening of the wires.

Refer to the installation manual of the outdoor unit for the
required field cable section and field fuse.

Remove maximum 8 

mm of the wire insulation when

connecting the wires to the terminals. 

Open the switch box cover. Pull the wires through rubber bush

(See figure 1)

  and connect them to the matching power

supply terminal.

NOTE

Observe the notes mentioned below when wiring to
the power supply terminal board.

Do not install the remote controller near a heater or in
a position exposed to direct sunlight.

Do not directly touch the PC board with your hand
during installation.

By installing an air suction and discharge filter, lifetime of
the unit can be prolonged.

Setting

Display interval

Mode n°

1st code n°

2nd code n°

light air filter 

contamination

±2500 hrs.

20

0

01

heavy air filter 
contamination

±1250 hrs.

20

0

02

Setting

Mode n°

1st code n°

2nd code n°

enabled

20

2

01

disabled

20

2

02

CAUTION for multi heat pump system

Enable the remote sensor when combined to a multi split
heat pump system.

When the thermostat is switched off in heating mode, the
expansion valve of the outdoor unit will not close
completely. Some refrigerant will pass through, causing a
temperature rise of the heat exchanger. The thermistor of
the unit is sensing a higher temperature than the actual
room temperature. This can cause a problem for the unit
during start up in heating mode. By enabling the thermistor
in the remote controller, the actual room temperature is
sensed instead of the heat exchanger temperature.

Summary of Contents for Split Series

Page 1: ...INSTALLATION MANUAL FDBQ25B8V1 Split series room air conditioners Multi system room air conditioners...

Page 2: ...1 2 4 5 6 3 1 2 3 4 5 6...

Page 3: ...e normativ e cu condi ia ca acestea s fie utilizate n conformitate cu instruc iunile noastre 19 skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi na...

Page 4: ...ORIES COULD RESULT IN ELECTRIC SHOCK SHORTCIRCUIT LEAKS FIRE OR OTHER DAMAGE TO THE EQUIPMENT BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT...

Page 5: ...rily Attach the hanger bracket to the suspension bolt Be sure to fix it securely by using a nut and washer on the upper and lower side of the hanger bracket and tighten the upper nut INSTALLING THE OU...

Page 6: ...Connector interface adaptor for sky air series When inserting the refrigerant piping in the wall hole take care not to let dust or moisture come into the piping Protect the pipes with a cap or seal t...

Page 7: ...n case of installing an electric heater execute the additional wiring and use a separate power supply of 1 50 Hz 230 V Use solid core cables to avoid loosening of the wires Refer to the installation m...

Page 8: ...emark wiring length up to 100 m Master slave unit system mode batting System operation mode cool or heat is determined by the mode the master unit is in When the master unit is in cool mode respective...

Page 9: ...NOTES NOTES...

Page 10: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW23698 1...

Reviews: