background image

 

Installation manual

 

1

FDBQ25B8V1

Split series room air conditioners

Multi system room air conditioners

4PW23698-1

C

ONTENTS

Page

Installing the indoor unit .................................................................... 1

Installing the outdoor unit .................................................................. 2

Refrigerant piping.............................................................................. 2

Drain piping ....................................................................................... 3

Vacuum drying of the installation ...................................................... 3

Field wiring ........................................................................................ 3

Installing the remote controller .......................................................... 4

Checklist............................................................................................ 5

Special features................................................................................. 5

Standard supplied accessories

Optional accessories

I

NSTALLING

 

THE

 

INDOOR

 

UNIT

Outlook drawing 

(See figure 1)

Selecting the location

The units are designed for ceiling concealed installation with an air
discharge duct of 500 mm.

Leave sufficient space for piping, servicing and electric wiring.

Be sure to install the unit so that:

the indoor and outdoor unit, the interconnection and the power
supply cable are at least 1 m away from televisions or radios.
This is to prevent interference from the air conditioner on your
televisions or radios.

the air will be distributed to the entire room.

the ceiling is strong enough to bear the weight of the indoor unit.

there are no obstructions for the air inlet and outlet.

the wall hole to the outdoor side for the electric wiring, the
refrigerant and drain piping can be made without problems in
terms of building structure.

Please consult with your dealer for installing in a special environment
(e.g. a place in oily surroundings, a place with sulfide gas, a place
where chemicals are used nearby, a place with big voltage
fluctuations, a place with volatile flammable gas, a place in which
machines generate electromagnetic waves).

FDBQ25B8V1

Split series room air  conditioners

Multi system room air conditioners

Installation manual

COMBINE THIS INDOOR UNIT WITH A DAIKIN
OUTDOOR UNIT ONLY!

READ THIS MANUAL CAREFULLY TO ENSURE
CORRECT INSTALLATION. BE SURE TO GIVE THE
CUSTOMER THE ENCLOSED OPERATION MANUAL.

REFER TO THE INSTALLATION MANUAL OF THE
OUTDOOR UNIT FOR THE ITEMS NOT DESCRIBED
BELOW.

Suction air filter 

1

Installation manual

Operation manual

1 of each

Wiring adaptor for electrical heater (KRP1B61)

Remote controller

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORTCIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT.   BE SURE
ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH
ARE SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL. 

IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.

OP

ER

ATI

ON

 MA

NU

AL

Eng

lish

Deu

tsc

h

Fra

nça

is

Ned

erla

nds

Esp

año

l

Ital

ian

o

ÏÏË

ÓÈο

Por

tug

ues

Dan

sk

Ins

talla

tion

 ma

nua

l

Spl

it S

yste

m a

ir c

ond

ition

ers

Ins

talla

tion

san

leitu

ng

Spl

it-B

aur

eih

e K

lima

ger

äte

Ma

nue

l d'i

nst

alla

tion

Clim

atis

eur

s d

e la

 sé

rie 

Spl

it

Mo

nta

geh

and

leid

ing

Spl

it-s

yste

em

 air

con

ditio

ner

s

Ma

nua

l de

 ins

tala

ción

Aco

ndi

cion

ado

res

 de

 air

e s

erie

 Sp

lit

Ma

nua

le d

'ins

talla

zion

e

Clim

atiz

zat

ori 

ser

ie S

plit

EÁ¯

ÂÈÚ

›‰ÈÔ

 ÂÁ

ηÙ

¿ÛÙ

·ÛË

˜

KÏÈ

Ì·Ù

ÈÛÙ

Èο

 Sp

lit

Ma

nua

l de

 ins

tala

ção

Apa

relh

os 

de 

ar c

ond

icio

nad

o d

a s

érie

 Sp

lit

Ins

talla

tion

sve

jled

nin

g

Klim

aan

lag

 i o

pde

lt sy

ste

m

FD

BQ

25B

7V1

Sp

lit 

ser

ies

 ro

om

 air

 co

ndi

tio

ner

s

Mu

lti 

sys

tem

 ro

om

 air

 co

ndi

tio

ner

s

Sp

lit 

ser

ies

 ro

om

 air

 co

ndi

tio

ner

s

Mu

lti 

sys

tem

 ro

om

 air

 co

ndi

tio

ner

s

INS

TAL

LAT

ION

 MA

NU

AL

Eng

lish

Deu

tsc

h

Fra

nça

is

Ned

erla

nds

Esp

año

l

Ital

ian

o

ÏÏË

ÓÈο

Por

tug

ues

Dan

sk

Ins

talla

tion

 ma

nua

l

Spl

it S

yste

m a

ir c

ond

ition

ers

Ins

talla

tion

san

leitu

ng

Spl

it-B

aur

eih

e K

lima

ger

äte

Ma

nue

l d'i

nst

alla

tion

Clim

atis

eur

s d

e la

 sé

rie 

Spl

it

Mo

nta

geh

and

leid

ing

Spl

it-s

yste

em

 air

con

ditio

ner

s

Ma

nua

l de

 ins

tala

ción

Aco

ndi

cion

ado

res

 de

 air

e s

erie

 Sp

lit

Ma

nua

le d

'ins

talla

zion

e

Clim

atiz

zat

ori 

ser

ie S

plit

EÁ¯

ÂÈÚ

›‰ÈÔ

 ÂÁ

ηÙ

¿ÛÙ

·ÛË

˜

KÏÈ

Ì·Ù

ÈÛÙ

Èο

 Sp

lit

Ma

nua

l de

 ins

tala

ção

Apa

relh

os 

de 

ar c

ond

icio

nad

o d

a s

érie

 Sp

lit

Ins

talla

tion

sve

jled

nin

g

Klim

aan

lag

 i o

pde

lt sy

ste

m

FD

BQ

25B

7V1

Never turn the circuit breaker ON until all the installation
work is completed!

Contact your Daikin dealer to confirm the outdoor unit
combination.

1

liquid pipe Ø6.4 mm or 1/4" Cut

2

gas pipe Ø9.52 mm or 3/8" Cut

3

drain socket OD=Ø27.2 ID=Ø21.6

4

rubber bush for wiring intake of the on/off-switch, the remote 
controller and the wiring adaptor for the electrical heater

5

rubber bush for wiring intake of the power supply

6

service space

7

switch box

8

switch box cover

9

screw for opening the switch box cover

Make sure that the indoor and outdoor unit is installed out
of reach for children!

Summary of Contents for Split Series

Page 1: ...INSTALLATION MANUAL FDBQ25B8V1 Split series room air conditioners Multi system room air conditioners...

Page 2: ...1 2 4 5 6 3 1 2 3 4 5 6...

Page 3: ...e normativ e cu condi ia ca acestea s fie utilizate n conformitate cu instruc iunile noastre 19 skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi na...

Page 4: ...ORIES COULD RESULT IN ELECTRIC SHOCK SHORTCIRCUIT LEAKS FIRE OR OTHER DAMAGE TO THE EQUIPMENT BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT...

Page 5: ...rily Attach the hanger bracket to the suspension bolt Be sure to fix it securely by using a nut and washer on the upper and lower side of the hanger bracket and tighten the upper nut INSTALLING THE OU...

Page 6: ...Connector interface adaptor for sky air series When inserting the refrigerant piping in the wall hole take care not to let dust or moisture come into the piping Protect the pipes with a cap or seal t...

Page 7: ...n case of installing an electric heater execute the additional wiring and use a separate power supply of 1 50 Hz 230 V Use solid core cables to avoid loosening of the wires Refer to the installation m...

Page 8: ...emark wiring length up to 100 m Master slave unit system mode batting System operation mode cool or heat is determined by the mode the master unit is in When the master unit is in cool mode respective...

Page 9: ...NOTES NOTES...

Page 10: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW23698 1...

Reviews: