background image

English 

6

COOLING, HEATING, AUTOMATIC, FAN, 
AND PROGRAM DRY OPERATION

Operate in the following order.

1

OPERATION MODE 
SELECTOR

Press OPERATION MODE SELECTOR 
button several times and select the 
OPERATION MODE of your choice as 
follows.

COOLING OPERATION

 

„

 ............................... “   ”

HEATING OPERATION

 

„

................................. “   ”

AUTOMATIC OPERATION

 

„

 ............................“ 

 ”

In this operation mode, COOL/HEAT change-

• 

over is automatically conducted.

FAN OPERATION

 

„

 ......................................... “   ”

DRY OPERATION

 

„

 ......................................... “ 

 ”

The function of this program is to decrease the 

• 

humidity in your room with the minimum tem-
perature decrease.
Micro computer automatically determines 

• 

TEMPERATURE and FAN SPEED.
This system does not go into operation if the 

• 

room temperature is below 60°F.

Refer to Fig. 3 on page [1]

2

ON/OFF

Press ON/OFF button.

OPERATION lamp lights up or goes off and the 
system starts or stops OPERATION.

[EXPLANATION OF HEATING OPERATION]

DEFROST OPERATION

As the frost on the coil of an outdoor unit in-

• 

crease, heating effect decreases and the system 
goes into DEFROST OPERATION.
The indoor unit fan stops and the remote control-

• 

ler display shows “ 

 ”.

After 6 to 8 minutes (maximum 10 minutes) of 

• 

DEFROST OPERATION, the system returns to 
HEATING OPERATION.

Regarding outside air temperature and 
heating capacity

The heating capacity of the air conditioner de-

• 

clines as the outside air temperature falls. In this 
case, use the air conditioner in combination with 
other heating systems.
A warm air circulating system is employed, and 

• 

therefore it takes some time until the entire room 
is warmed up after the start of operation.
An indoor fan runs to discharge a gentle wind 

• 

automatically until the temperature inside the air 
conditioner reaches a certain level. At this time, 
the remote controller displays “ 

 ”. Leave it 

as it stands and wait for a while.
When the warm air stays under the ceiling and 

• 

your feet are cold, we recommend that you use a 
circulator (a fan to circulate the air inside the 
room). For details, consult your dealer.

ADJUSTMENT

For programming TEMPERATURE, FAN SPEED 
and AIR FLOW DIRECTION, follow the procedure 
shown below.

TEMPERATURE SETTING

Press TEMPERATURE SETTING button and 
program the setting temperature.

Each time this button is pressed, 
setting temperature rises 1°F.

Each time this button is pressed, 
setting temperature lowers 1°F.

The setting is impossible for fan operation.

• 

 NOTE

The setting temperature range of the remote 

 

controller is 60°F to 90°F.

FAN SPEED CONTROL

Press FAN SPEED CONTROL button.

High or Low fan speed can be selected.
The micro computer may sometimes control the 
fan speed in order to protect the unit.

01_EN_3PN07753-11N.indd   6

01_EN_3PN07753-11N.indd   6

12/19/2008   8:00:31 PM

12/19/2008   8:00:31 PM

Summary of Contents for SkyAir FHQ18PVJU

Page 1: ...e reference This manual should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre...

Page 2: ...1 TEST F hr hr TEST NOT AVAILABLE L H 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 1 j a i h f c e e d d g b d f e k 3 F hr H 2 4...

Page 3: ...rollers control 1 indoor unit The unit is individually operated NOTE Contact your dealer in case of 2 remote control lers control system Names and functions of parts Refer to Fig 2 on page 1 a Indoor...

Page 4: ...n If equipment utilizing a burner is used in the same room as the air conditioner there is the danger of oxygen deficiency which could lead to an asphyxiation hazard resulting in serious injury or dea...

Page 5: ...or works of art Do not place items under the indoor unit which may be damaged by water Condensation may form if the humidity is above 80 or if the drain outlet gets blocked Avoid placing the controll...

Page 6: ...Regarding places for installation Is the air conditioner installed at a well venti lated place where there are no obstacles around Do not use the air conditioner in the follow ing places a Filled with...

Page 7: ...SPLAY FAN SPEED This display shows the set fan speed 9 DISPLAY AIR FLOW FLAP Refer to AIR FLOW DIRECTION ADJUST 10 DISPLAY TIME TO CLEAN AIR FILTER Refer to HOW TO CLEAN THE AIR FILTER 11 DISPLAY DEFR...

Page 8: ...e and heating capacity The heating capacity of the air conditioner de clines as the outside air temperature falls In this case use the air conditioner in combination with other heating systems A warm...

Page 9: ...At defrost opera tion Operation mode includes automatic operation PROGRAM TIMER OPERATION Operate in the following order The timer is operated in the following two ways Programming the stop time The s...

Page 10: ...ty is being used even if the system is not operating Turn off the main power supply switch for saving energy When reoperating turn on the main power supply switch 6 hours before opera tion for smooth...

Page 11: ...Do not use gasoline benzene thinner polishing powder liquid insecticide It may cause discolor ing or warping Do not scrub firmly when washing the blade with water The surface sealing may peel off Do n...

Page 12: ...system After 3 minutes the system will turn on again automatically The system does not start when the display shows UNDER CENTRALIZED CONTROL and it flashes for a few seconds after pressing an operat...

Page 13: ...f a safety device such as a fuse a breaker or an earth leakage breaker frequently actuates Measure Do not turn on the main power switch If the ON OFF switch does not properly work Measure Turn off the...

Page 14: ...to ADJUSTMENT If the FAN SPEED button is set to LOW SPEED Refer to ADJUSTMENT If the air flow direction is not proper Refer to AIR FLOW DIRECTION ADJUST If the doors or the windows are open Shut door...

Page 15: ...3PN07753 11N EM08A092 0902 HT...