background image

English 

4

Arrange the drain pipe to ensure smooth 

• 

drainage. Incomplete drainage may cause 
wetting of the building, furniture etc.
Do not place the controller exposed to direct 

• 

sunlight.

The LCD display may get discolored, failing to 
display the data.

Do not wipe the controller operation panel 

• 

with benzine, thinner, chemical dustcloth, etc.

The panel may get discolored or the coating 
peeled off. If it is heavily dirty, soak a cloth in 
water-diluted neutral detergent, squeeze it well 
and wipe the panel clean. And wipe it with an-
other dry cloth.

Dismantling of the unit, treatment of the re-

• 

frigerant, oil and eventual other parts, should 
be done in accordance with the relevant local 
and national regulations.
Do not dry the fi lter by exposing it to direct 

 

sunlight or warming it using fi re, etc. Doing 
so can result in the deformation of the fi lter.

OPERATION RANGE

3. 

If the temperature or the humidity is beyond the 
following conditions, safety devices may work and 
the air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.

OUTDOOR 
UNIT

OPERATION

TEMPERATURE (

°

F)

OUTDOOR

INDOOR

RZQ18·24·
30PVJU

COOLING

23 to 115 (DB) 57 to 77 (WB)

HEATING

0 to 60 (WB)

59 to 80.5 (DB)

D B: Dry bulb temperature (°F)
WB: Wet bulb temperature (°F)

The setting temperature range of the remote con-
troller is 60°F to 90°F.

INSTALLATION SITE

4. 

Regarding places for installation

Is the air conditioner installed at a well-venti-

• 

lated place where there are no obstacles 
around?
Do not use the air conditioner in the follow-

• 

ing places.

a.  Filled with much mineral oil such as cutting oil
b.  Where there is much salt such as a beach 

area

c.  Where sulfured gas exists such as a hot-

spring resort

d.  Where there are considerable voltage fl uctua-

tions such as a factory or plant

e.  Vehicles and vessels
 f .   Where there is much spray of oil and vapor 

such as a cookery, etc.

g.  Where there are machines generating electro-

magnetic waves

h.  Filled with acid and/or alkaline steam or vapor

Is a snow protection measure taken?

• 

For details, consult your dealer.

Regarding wiring

All wiring must be performed by an autho-

• 

rized electrician.

To do wiring, ask your dealer. Never do it by 
yourself.

Make sure that a separate power supply cir-

• 

cuit is provided for this air conditioner and 
that all electrical work is carried out by quali-
fi ed personnel according to local laws and 
regulations.

Pay attention to running noises, too

Are the following places selected?

• 

a.  A place that can suffi ciently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b.  A place where the hot wind discharged from 

the air outlet of the outdoor unit and the run-
ning noises.

Are you sure that there are no obstacles near 

• 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

If abnormal noises occur in use, consult your 

• 

dealer.

01_EN_3PN07753-11N.indd   4

01_EN_3PN07753-11N.indd   4

12/19/2008   8:00:30 PM

12/19/2008   8:00:30 PM

Summary of Contents for SkyAir FHQ18PVJU

Page 1: ...e reference This manual should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre...

Page 2: ...1 TEST F hr hr TEST NOT AVAILABLE L H 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 1 j a i h f c e e d d g b d f e k 3 F hr H 2 4...

Page 3: ...rollers control 1 indoor unit The unit is individually operated NOTE Contact your dealer in case of 2 remote control lers control system Names and functions of parts Refer to Fig 2 on page 1 a Indoor...

Page 4: ...n If equipment utilizing a burner is used in the same room as the air conditioner there is the danger of oxygen deficiency which could lead to an asphyxiation hazard resulting in serious injury or dea...

Page 5: ...or works of art Do not place items under the indoor unit which may be damaged by water Condensation may form if the humidity is above 80 or if the drain outlet gets blocked Avoid placing the controll...

Page 6: ...Regarding places for installation Is the air conditioner installed at a well venti lated place where there are no obstacles around Do not use the air conditioner in the follow ing places a Filled with...

Page 7: ...SPLAY FAN SPEED This display shows the set fan speed 9 DISPLAY AIR FLOW FLAP Refer to AIR FLOW DIRECTION ADJUST 10 DISPLAY TIME TO CLEAN AIR FILTER Refer to HOW TO CLEAN THE AIR FILTER 11 DISPLAY DEFR...

Page 8: ...e and heating capacity The heating capacity of the air conditioner de clines as the outside air temperature falls In this case use the air conditioner in combination with other heating systems A warm...

Page 9: ...At defrost opera tion Operation mode includes automatic operation PROGRAM TIMER OPERATION Operate in the following order The timer is operated in the following two ways Programming the stop time The s...

Page 10: ...ty is being used even if the system is not operating Turn off the main power supply switch for saving energy When reoperating turn on the main power supply switch 6 hours before opera tion for smooth...

Page 11: ...Do not use gasoline benzene thinner polishing powder liquid insecticide It may cause discolor ing or warping Do not scrub firmly when washing the blade with water The surface sealing may peel off Do n...

Page 12: ...system After 3 minutes the system will turn on again automatically The system does not start when the display shows UNDER CENTRALIZED CONTROL and it flashes for a few seconds after pressing an operat...

Page 13: ...f a safety device such as a fuse a breaker or an earth leakage breaker frequently actuates Measure Do not turn on the main power switch If the ON OFF switch does not properly work Measure Turn off the...

Page 14: ...to ADJUSTMENT If the FAN SPEED button is set to LOW SPEED Refer to ADJUSTMENT If the air flow direction is not proper Refer to AIR FLOW DIRECTION ADJUST If the doors or the windows are open Shut door...

Page 15: ...3PN07753 11N EM08A092 0902 HT...