background image

English 

8

When the timer is programmed to stop the system 
after 3 hours and start the system after 4 hours, 
the system will stop after 3 hours and then 1 hour 
later the system will start.

After the timer is programmed, the display shows 

• 

the remaining time.
Press the TIMER ON/OFF button once again to 

• 

cancel programming. The display vanishes.

OPTIMUM OPERATION

7. 

Observe the following precautions to ensure the 
system operates.

Adjust the room temperature properly for a com-

• 

fortable environment. Avoid excessive heating or 
cooling.
Prevent direct sunlight from entering a room 

• 

during cooling operation by using curtains or 
blinds.
Ventilate the room regularly.

• 

Using the unit for long periods of time requires 
attentive ventilation of the room.
Keep doors and windows closed. If the doors 

• 

and windows remain open, room air will fl ow out 
and cause to decrease the effect of cooling and 
heating.
Do not place other heaters directly below the 

• 

indoor unit.
They may deform due to the heat.
Never place objects near the air inlet and the air 

• 

outlet of the unit. It may cause deterioration in 
the effect or stop in the operation.
Turn off the main power supply switch when it is 

• 

not used for long periods of time. When the main 
power switch is turned on, some watts of elec-
tricity is being used even if the system is not 
operating. Turn off the main power supply switch 
for saving energy. When reoperating, turn on the 
main power supply switch 6 hours before opera-
tion for smooth running (Refer to “MAINTE-
NANCE”).
When the display shows “ 

• 

 ” (TIME TO 

CLEAN AIR FILTER), ask a qualifi ed service 
person to clean the fi lters (Refer to “MAINTE-
NANCE”).

MAINTENANCE

8. 

(FOR SERVICE PERSONNEL)

ONLY A QUALIFIED SERVICE PERSON IS 
ALLOWED TO PERFORM MAINTENANCE

IMPORTANT!

BEFORE OBTAINING ACCESS TO TERMINAL 

• 

DEVICES, ALL POWER SUPPLY CIRCUITS 
MUST BE INTERRUPTED

To clean the air conditioner, be sure to stop op-

• 

eration, and turn the power switch off. Otherwise, 
an electric shock and injury may result.
Do not wash the air conditioner with water.

• 

Doing so may result in an electric shock.
Be careful with a scaffold or staging.

• 

Caution must be exercised because of work at a 
high place.

HOW TO CLEAN THE AIR FILTER

Clean the air fi lter when the display shows “ 

 ” 

(TIME TO CLEAN AIR FILTER). 
Increase the frequency of cleaning if the unit is 
installed in a room where the air is extremely 
contaminated.
If the dirt becomes impossible to clean, change the 
air fi lter (Contact your dealer when you exchange 
air fi lter.).

Fig.5

Knob

Fig.6

Tab

Hook

Open the suction grille.

1. 

Slide knobs (×2) simultaneously as shown and 
then pull them downward. (Do the same proce-
dure for closing.) 

(Refer to Fig. 5)

Remove the air fi lters.

2. 

Push the 2 tabs up, and remove slowly lower 
the air fi lter. 

(Refer to Fig. 6)

01_EN_3PN07753-11N.indd   8

01_EN_3PN07753-11N.indd   8

12/19/2008   8:00:32 PM

12/19/2008   8:00:32 PM

Summary of Contents for SkyAir FHQ18PVJU

Page 1: ...e reference This manual should be left with the equipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre...

Page 2: ...1 TEST F hr hr TEST NOT AVAILABLE L H 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 1 j a i h f c e e d d g b d f e k 3 F hr H 2 4...

Page 3: ...rollers control 1 indoor unit The unit is individually operated NOTE Contact your dealer in case of 2 remote control lers control system Names and functions of parts Refer to Fig 2 on page 1 a Indoor...

Page 4: ...n If equipment utilizing a burner is used in the same room as the air conditioner there is the danger of oxygen deficiency which could lead to an asphyxiation hazard resulting in serious injury or dea...

Page 5: ...or works of art Do not place items under the indoor unit which may be damaged by water Condensation may form if the humidity is above 80 or if the drain outlet gets blocked Avoid placing the controll...

Page 6: ...Regarding places for installation Is the air conditioner installed at a well venti lated place where there are no obstacles around Do not use the air conditioner in the follow ing places a Filled with...

Page 7: ...SPLAY FAN SPEED This display shows the set fan speed 9 DISPLAY AIR FLOW FLAP Refer to AIR FLOW DIRECTION ADJUST 10 DISPLAY TIME TO CLEAN AIR FILTER Refer to HOW TO CLEAN THE AIR FILTER 11 DISPLAY DEFR...

Page 8: ...e and heating capacity The heating capacity of the air conditioner de clines as the outside air temperature falls In this case use the air conditioner in combination with other heating systems A warm...

Page 9: ...At defrost opera tion Operation mode includes automatic operation PROGRAM TIMER OPERATION Operate in the following order The timer is operated in the following two ways Programming the stop time The s...

Page 10: ...ty is being used even if the system is not operating Turn off the main power supply switch for saving energy When reoperating turn on the main power supply switch 6 hours before opera tion for smooth...

Page 11: ...Do not use gasoline benzene thinner polishing powder liquid insecticide It may cause discolor ing or warping Do not scrub firmly when washing the blade with water The surface sealing may peel off Do n...

Page 12: ...system After 3 minutes the system will turn on again automatically The system does not start when the display shows UNDER CENTRALIZED CONTROL and it flashes for a few seconds after pressing an operat...

Page 13: ...f a safety device such as a fuse a breaker or an earth leakage breaker frequently actuates Measure Do not turn on the main power switch If the ON OFF switch does not properly work Measure Turn off the...

Page 14: ...to ADJUSTMENT If the FAN SPEED button is set to LOW SPEED Refer to ADJUSTMENT If the air flow direction is not proper Refer to AIR FLOW DIRECTION ADJUST If the doors or the windows are open Shut door...

Page 15: ...3PN07753 11N EM08A092 0902 HT...