7 Technical data

Installation manual

18

250D7Y1B

Sky Air Advance-series

4P573384-1 – 2019.04

7.3

Wiring diagram: Outdoor unit

The wiring diagram is delivered with the unit, located at the inside of
the service cover.

(1) Connection diagram

English

Translation

Connection diagram

Connection diagram

Only for ***

Only for ***

See note ***

See note ***

Outdoor

Outdoor

Indoor

Indoor

Upper EEV

Upper electronic expansion valve

Lower EEV

Lower electronic expansion valve

Fan

Fan

ON

ON

OFF

OFF

(2) Layout

English

Translation

Layout

Layout

Front

Front

Left

Left

Back

Back

Position of compressor terminal

Position of compressor terminal

(3) Notes

English

Translation

Notes

Notes

Connection

X1M

Indoor/outdoor communication

Earth wiring

Field supply

Protective earth

Field wire

Wiring depending on model

Option

Switch box

PCB

NOTES:

1

Refer to the wiring diagram sticker (on the back of the front
plate) for how to use the BS1~BS3 and DS1+DS2 switches.

2

When operating, do not short-circuit protective devices S1PH
and S1PL.

3

Refer to the combination table and the option manual for how
to connect the wiring to X6A, X15A and X77A.

4

Colours: BLK: black, RED: red, BLU: blue, WHT: white, GRN:
green

(4) Legend

English

Translation

Legend

Legend

Optional

Optional

Part n°

Part n°

Description

Description

A1P

Printed circuit board (main)

A2P

Printed circuit board (noise filter)

A3P

Printed circuit board (inverter)

A4P

Printed circuit board (fan)

A5P

*

Printed circuit board (demand)

C503, C506 C507
(A3P)

Capacitor

DS1,DS2 (A1P)

DIP switch

E1H

*

Bottom plate heater

E1HC

Crankcase heater

F1U (A1P)

Fuse (T 3.15 A 250 V)

F8U, F9U

*

Fuse (F)

F101U (A4P)

Fuse

F101U, F102U (A2P)

Fuse

F601U (A3P)

Fuse

HAP (A1P, A3P,
A4P)

LED (service monitor is green)

K1R (A1P)

Magnetic relay (Y2S)

K3R (A3P)

Magnetic relay

K3R (A1P)

Magnetic relay (Y3S)

K5R (A1P)

Magnetic relay (E1HC)

K7R (A1P)

Magnetic relay (E1H)

L1R

Reactor

M1C

Compressor motor

M1F

Fan motor

PS (A1P,A3P)

Switching power supply

Q1DI

Earth leakage circuit breaker

Q1LD (A1P)

Earth current detector

R1T (A1P)

Thermistor (air)

R2T

Thermistor (discharge pipe)

R3T

Thermistor (suction pipe)

R4T

Thermistor (heat exchanger exit)

R5T

Thermistor (heat exchanger branch)

R6T

Thermistor (liquid pipe)

R7T

Thermistor (M1C body)

R24 (A4P)

Resistor (current sensor)

R300 (A3P)

Resistor (current sensor)

S1PH

High pressure switch

S1PL

Low pressure switch

SEG1~SEG3 (A1P)

7‑segment display

T1A

Current sensor

V1D (A3P)

Diode

V1R (A3P, A4P)

Diode module

X*A

Connector

X*M

Terminal block

Y1E

Electronic expansion valve (main)

Y2E

Electronic expansion valve (injection)

Y2S

Solenoid valve (4‑way valve)

Y3S

Solenoid valve (pressure equalization)

Z*C

Noise filter (ferrite core)

Z1F

Noise filter

Summary of Contents for Sky Air Advance Series

Page 1: ...Installation manual Sky Air Advance series English Installation manual Sky Air Advance series RZA200D7Y1B RZA250D7Y1B...

Page 2: ...HD HU 200 1000 1000 500 HD HU A B C 200 1 300 1000 A B C E 200 1 300 1000 1000 500 D 1000 D E 1000 1000 500 B D HD HU 300 1000 250 1500 300 1500 B D E HB HU 300 1000 1000 500 HU HB HU 300 1250 1000 50...

Page 3: ...6 17 Direktiver med senere ndringer Direktiv med f retagna ndringar Direktiver med foretatte endringer Direktiivej sellaisina kuin ne ovat muutettuina v platn m zn n Smjernice kako je izmijenjeno ir n...

Page 4: ...staava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplota TS...

Page 5: ...sioning 14 5 2 To perform a test run 15 5 3 Error codes when performing a test run 16 6 Disposal 16 7 Technical data 17 7 1 Service space Outdoor unit 17 7 2 Piping diagram Outdoor unit 17 7 3 Wiring...

Page 6: ...ance or an operating electric heater 3 1 1 Installation site requirements of the outdoor unit Mind the spacing guidelines See the Technical data chapter and the figures on the inside of the front cove...

Page 7: ...ze between the heat exchanger and the casing of the unit This might decrease the operating efficiency INFORMATION We suggest to install the optional bottom plate heater EKBPH250D7 when the unit is ins...

Page 8: ...tation of the bends NOTICE Always protect the surrounding surfaces e g wiring insulation foam from heat when brazing 6 Do the following Insulate the liquid piping a and the gas piping b Wind heat insu...

Page 9: ...copper flare 4 3 3 To perform vacuum drying To remove all moisture from the system proceed as follows 1 Check that with the vacuum pump turned off the target vacuum is maintained for at least 1 hour 4...

Page 10: ...the refrigerant This product contains fluorinated greenhouse gases Do NOT vent gases into the atmosphere Refrigerant type R32 Global warming potential GWP value 675 WARNING FLAMMABLE MATERIAL The refr...

Page 11: ...70 R1 0 45 0 9 1 35 1 8 2 25 2 7 3 15 Standard liquid pipe size Length m 0 10 10 20 20 30 30 40 40 50 50 60 60 70 R2 0 2 0 4 0 6 0 8 1 1 2 1 4 Size up liquid pipe size Length m 0 5 5 10 10 15 15 20 20...

Page 12: ...refrigerant WARNING Only use R32 as refrigerant Other substances may cause explosions and accidents R32 contains fluorinated greenhouse gases Its global warming potential GWP value is 675 Do NOT vent...

Page 13: ...18 6 A 19 9 A Voltage range 380 415 V Phase 3N Frequency 50 Hz Wire sizes Must comply with applicable legislation Interconnection cables H05VV U4G2 5 Recommended field fuse 20 A Earth leakage circuit...

Page 14: ...ck the insulation resistance of the compressor NOTICE If after installation refrigerant accumulates in the compressor the insulation resistance over the poles can drop but if it is at least 1 M then t...

Page 15: ...e lit For any other action it needs to be lit first The backlight is lit for 30 seconds when you press a button 1 Perform introductory steps Action 1 Open the liquid stop valve and gas stop valve by r...

Page 16: ...ase of three phase power supply units Note Operation will be impossible Turn OFF the power recheck the wiring and switch two of the three electrical wires L4 The air inlet or air outlet is blocked U0...

Page 17: ...m distance between the unit and the edge of obstacle E in the direction of obstacle D HU Height of the unit HB HD Height of obstacles B and D 1 Seal the bottom of the installation frame to prevent dis...

Page 18: ...d Legend Optional Optional Part n Part n Description Description A1P Printed circuit board main A2P Printed circuit board noise filter A3P Printed circuit board inverter A4P Printed circuit board fan...

Page 19: ......