Humidifying Rotor Motor
Si001362E
6
Removal Procedure
3. Humidifying Rotor Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Remove the humidifying
rotor.
1
Release the
hygroscopic fan motor
lead wire from the hook.
2
Remove the bell mouth.
3
Remove the
humidifying rotor.
2. Remove the humidifying
rotor motor.
1
2
Disconnect the
humidifying rotor motor
lead wire.
Remove the 2 screws
and remove the
humidifying rotor motor.
Hook
Hygroscopic fan motor
lead wire
(R19576)
Bell mouth
(R19577)
(R19578)
Humidifying
rotor
(R19579)
Humidifying
rotor motor
Humidifying rotor
motor lead wire