Heater Assembly
Si001362E
4
Removal Procedure
2. Heater Assembly
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Inner structure of the
humidifier unit
2. Remove the heater
assembly.
1
2
Release the harnesses
from the hook.
Remove the 3 screws
and remove the duct
(adsorption side).
3
Release the harnesses
from the 3 hooks.
When reassembling, these
harnesses must be fit in the
following hooks.
• Humidifying rotor motor
•
Damper motor
•
Limit switch
•
Humidifying thermistor
→
Hook (a) and hook (b)
•
Hygroscopic fan motor
→
Hook (b) and hook (c)
•
Heater
→
Hook (c) only
Hook
Duct
(adsorption side)
Hygroscopic fan
motor harness
Heater
assembly
Humidifier
fan motor
Humidifying
rotor motor
Damper
motor
Humidifying
thermistor
(R19571)
Hook
Duct
(adsorption side)
(R19572)
Hook (a)
Hook (c)
Hook (b)
(R19573)