![background image](http://html1.mh-extra.com/html/daikin/rxz25nv1b/rxz25nv1b_service-manual_2459983014.webp)
Outer Panels / Outdoor Fan / Fan Motor
Si001362E
12
Removal Procedure
3. Remove the outdoor fan.
1
2
Disconnect the
connector [S70].
Release the fan motor
lead wire from the 5
hooks.
[S70]: fan motor
3
Remove the nut and
remove the outdoor fan.
Nut size: M6
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
When reassembling, put the
fan motor lead wire through
the back of the fan motor (so
as not to be entangled with
the outdoor fan).
Step
Procedure
Points
Hook
[S70]
(R19596)
Hook
Nut
(R19597)
Outdoor fan
10 mm
(0.39 inch)
(R18954)
(R3249)
Lead wire
Outdoor fan