Four Way Valve / Electronic Expansion Valve
Si001362E
26
Removal Procedure
3
Remove the putties and
shield plate.
Be careful so as not to burn
the compressor terminals or
the name plate.
4
5
Remove the terminal
cover and the
protecting bushing.
Disconnect the
compressor lead wires
and detach the
overload protector.
6
7
Heat up the 4 brazed
parts of the four way
valve in the order of (a)
(b) (c) (d).
Remove the four way
valve.
Step
Procedure
Points
Shield plate
(R19636)
(R19637)
Terminal
cover
Compressor
lead wire
U (red)
W (blue)
V (yellow)
Protective
bushing
Overload
protector
(R19638)
(a)
(b)
(c)
(d)
Four way valve