![background image](http://html1.mh-extra.com/html/daikin/rxz25nv1b/rxz25nv1b_service-manual_2459983024.webp)
Reactor / Thermistor Assembly / Partition Plate
Si001362E
22
Removal Procedure
3. Release the discharge
pipe thermistor.
Since the piping ports on
the sound blanket are torn
easily, remove the sound
blanket carefully.
1
2
Open the sound blanket
(top).
Open the front of the
sound blanket (outer).
3
Detach the discharge
pipe thermistor.
Be careful not to lose the
fixture for the discharge pipe
thermistor.
When reassembling, meet
the edge of the thermistor
and the fixture.
4. Release the liquid pipe
thermistor.
1
2
Open the right side of
the sound blanket
(outer).
Detach the liquid pipe
thermistor.
Be careful not to lose the
clip for the thermistor.
Step
Procedure
Points
(R19626)
Sound blanket (top)
Sound blanket
(outer)
Discharge pipe
thermistor
(R19627)
(R18789)
Fixture
(R19628)
Liquid pipe thermistor
(R3264)
Clip