Electrical Box
Si001362E
18
Removal Procedure
7
Disconnect the 4
terminals from the
reactor.
When reassembling, match
the color of the sleeve with
the label on the reactor.
right: yellow
left: red
You can connect 2
harnesses of the same color
into either upper or lower.
3. Remove the electrical box.
1
Remove the screw in
front of the electrical
box.
2
Lift up the electrical box
and remove it.
Step
Procedure
Points
Reactor
(R19614)
Label
(R20301)
(R19615)
Electrical box