![background image](http://html1.mh-extra.com/html/daikin/rxs-l3/rxs-l3_technical-data-manual_2459939006.webp)
• Outdoor Unit • RXS-L3
2
• Split - Sky Air • RXS-L3
4
2
Specifications
Notes
(1) Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
(2) 220V
(3) 230V
(4) 240V
(5) EER/COP according to Eurovent 2012, for use outside EU only
2-2 Capacity and Power input
FCQG35F/RXS35L3
Indoor unit
FCQG35F
Outdoor unit
RXS35L3
Cooling capacity
Min.
kW
1.3
Btu/h
4,430
kcal/h
1,120
Nom.
kW
3.4 (1)
Btu/h
11,590 (1)
kcal/h
2,920 (1)
Max.
kW
4.0
Btu/h
13,640
kcal/h
3,440
Heating capacity
Min.
kW
1.3
Btu/h
4,430
kcal/h
1,120
Nom.
kW
4.20 (1)
Btu/h
14,320 (1)
kcal/h
3,610 (1)
Max.
kW
5.2
Btu/h
17,730
kcal/h
4,470
Power input
Cooling
Min.
kW
0.400
Nom.
kW
0.909 (1)
Max.
kW
1.100
Heating
Min.
kW
0.230
Nom.
kW
1.200 (1)
Max.
kW
1.840
Seasonal efficiency
(according to
EN14825)
Cooling
Energy label
A++
Pdesign
kW
3.50
SEER
6.35
Annual energy
consumption
kWh
193
Heating (Average
climate)
Energy label
A++
Pdesign
kW
3.32
SCOP/A
4.90
Annual energy
consumption
kWh
949
Piping connections
Liquid
OD
mm
6.35
Gas
OD
mm
9.5
Drain
OD
mm
VP25 (External dia.32 / internal dia. 25)
Heat insulation
Both liquid and gas pipes
Current
Nominal running
current (RLA) - 50Hz
Cooling
A
4.02 (2) / 3.83 (3) / 3.64 (4)
Heating
A
5.40 (2) / 5.10 (3) / 4.90 (4)
Nominal efficiency
EER
3.74 (5)
COP
3.50 (5)
Annual energy consumption
kWh
455
Energy label
Cooling
A
Heating
B